Instruction Manual MM850402 ed. 08b
12
1.1.5
Flue gas probes
Probes Code
Description
BB610043
90° FIXED long L=180mm+180mm Ø8mm TcK
BB610046
FIXED hose length 3mt L=300mm Ø8mm TcK
BB610047
FIXED hose length 2,5mt L=180mm Ø6mm TcK
BB610048
FIXED hose length 2,5mt L=300mm Ø6mm TcK
BB610051
FIXED hose length 3mt L=180mm Ø8mm TcK
BB610080
FIXED hose length 3mt L=750mm Ø8mm TcK
BB610081
FIXED INCONEL hose length 3mt L=750mm Ø8mm TcK
BB610112
FIXED 90° hose length 2,5mt L=300mm+450mm Ø8mm TcK
BB610119
FIXED hose length 3mt L=500mm Ø8mm TcK
BB610122
FIXED 90° hose length 2,5mt L=200mm+300mm Ø8mm TcK
1.2 Specifications
Type
: 2, 3 or 4 cells hand-held flue gas analyser/Boiler tuning unit.
Calibration
: automatic 60 secs. calibration procedure at instrument switching-on. Optional autozero electrovalve for
quick start-up
Self-diagnosis
: Sensors efficiency test with anomalous status announcement.
Fuel types
: Up to 10 totally programmable.
Pump
: rate of flow 0.8 lit / head –230mbar
All data measured using 3 meters long probe and line filter connected. Load loss = 10 mbar using a 3 meters probe
extension
Power supply
: High capacity Li-ion rechargeable battery pack / external battery charger.
Charging time :
3h at 90% with instrument off.
Battery life
: 10h continuous operation (without printer and back-light).
Printer
: Impact type 24 columns with 58 mm large and 18 meters long paper roll
Printer power supply
: using the analyser battery pack.
Automatic CO(ppm) dilution
: Automatic sensor protection from high CO concentration.
Internal data memory
: up to 250 complete analysis data structured by Tags.
Service and user data
: 3 programmable lines for each programmed customer using a PC and DBGas Software.
Report Header
: 4 rows x 16 characters programmable from keyboard
Display
: Large (40x56 mm) graphic LCD display with automatic back-light device. Bargraph and trend capability as
option.
Serial interface
: USB standard interface.
Smoke measurement
: Using the optional external manual pump. Bacharach index memory store and printout
capability as standard.
Optional probes
: ambient CO, explosive gas leakage sniffer.
Working temperature
: from –5°C to +45 °C (up to 50°C for short time)
Storage temperature
: from –20 to +50°C (3 months maximum at temperatures exceeding the operational limits).
Dimensions
: 115x90x330 mm
Weight
: Nett. 1.1 kg battery and printer included
External Probes
Ambient CO probe
Range:
from 0 to 500ppm
Accuracy:
±
5ppm up to 100ppm;
±
5% up to 500ppm
Resolution:
1ppm
Response time:
30s (t90)
Waiting starting time:
30s
Working temperature
: from –5°C to +45 °C