Support for Association Groups

ZW47 supports 3 association groups. Group 1 support 1 node ID,Group 2--3 Support maximum of 5 node ID’s 

Association group_1:Z-Wave Plus Lifeline
     Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW47 Status change report, 
             1. ZW47 will trigger AUTO report function if the Switch status had been changed.
Association group_2:basic set command

    send out a related  basic set command.   On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command

    send out a related  basic set command.   On (0xFF) or Off (0x00) to its associated group.

Support for Overload Protection 

ZW47 support Overload Protection ,When the ZW47 load exceeds the overload setting value, the overload signal is sent out
Notification Type : Overload  0x08 .  Event :Overload detected  0x08

Restoring Factory Defaults

ZW47 is removed from the network and will be restored to the factory setting

All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.

   When the output of the ZW47 Enpoint2 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically

   When the output of the ZW47 Enpoint1 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically