background image

Introduction:

The ZW96S is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network.

around obstacles and radio dead spots to ensure that the signal is received at its intended destination.

ZW96S is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.

Key Features:

 ---Remote ON/OFF control via the Z-Wave controller
 ---Manual ON/OFF control with the front panel push button
 ---Support Association Group and Auto Report switch status
 ---Over temperature protection
 ---Support firmware upgrades via Over-the-air (need Gateways support)

Product Overview:

A     AC plug

C     Z-Wave controlled outlet
D     ON/OFF/PROG Push button
E     Status LED

Z-Wave Remote Control

ADD or Remove the ZW96 from the existing Z-Wave home control network with your primary controller.
 ---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.

Include ZW96S to/from a Z-Wave Gateway with supporting Security.The ZW96S can support the Primary Controller that implemented the security S2.

Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by 

Z-WaveTM Controller means “Remove” or “Exclusion”.

z-wave protocol Command Class Node Info 

Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal

 ---When prompted by your primary controller, click the PROG button five times in one second.

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.

D

C

E

A

z-wave protocol Command Class Node Info 

COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4

The Below listed Command Class are all supported the Security S2

  COMMAND_CLASS_VERSION,
  COMMAND_CLASS_MANUFACTURER_SPECIFIC,
  COMMAND_CLASS_DEVICE_RESET_LOCALLY,
  COMMAND_CLASS_ASSOCIATION,
  COMMAND_CLASS_ASSOCIATION_GRP_INFO,
  COMMAND_CLASS_POWERLEVEL,
  COMMAND_CLASS_SWITCH_BINARY,
  COMMAND_CLASS_CONFIGURATION,

  COMMAND_CLASS_NOTIFICATION_V8,

  COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4

Z-Wave Configuration Parameters

 1:Status LED Configuration
      Paramter No: 1(0x01)     Size:1 Byte    Value: 00(default)   outlet on,led on.
                                                                        Value: 01                outlet on,led off.
                                                                        Value: 02                led off, led no work.

You may use the below configuration parameters to change settings of the corresponding functionality.

                                                                        Value: 02                led off, led no work.
2:Count Down Configuration(The countdown time, the socket closed)
      Paramter No: 2(0x02)     Size:2 Byte    Value: 00 00(default)   no timer.
        Value Scope :0----36000S(Countdown time can be set