background image

Support for Association Groups

ZW96 supports 2 association groups. A maximum of 5 node ID’s (nonmulti-channel devices) can be assigned to these association groups.
Association group_1: Z-Wave Plus Lifeline Maximum 5 node
     Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW96 Status change report, 

             1. ZW96S will trigger AUTO report function if the Switch status had been changed.
             2. Device Reset Locally Notification(Only report when the ZW96S Switch Module has been triggered the RESET TO DEFAULT)
Association group_2:  basic set command

     On (0xFF) or Off (0x00) to its associated group.

Support for Over temperature protection

ZW96S support Over temperature protection,When the temperature is greater than 105 degrees Celsius, the Heat Alarm signal is sent out
Notification Type : Heat  Alarm  0x04 .  Event :Overheat detected  0x02

Restoring Factory Defaults

All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.

When the device is removed from the host, it is returned to the factory settings

MANUAL RESET

 ---Power off ZW96S

 ---keep holding the PROG button

 ---Power on,Press and keep holding the PROG button for no less than 10 seconds.

Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.

     When the output of the ZW96S socket is changed, On (0xFF) or Off (0x00). The ZW96S will automatically send out a related  basic set

Reviews: