Association group_1:Z-Wave Plus Lifeline
     Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW97 Status change report, 
             1. ZW97 will trigger AUTO report function if the Switch status had been changed.
             2. When ZW97 high temperature alarm sends out notifications or releases notifications, ZW97 will auto report
Association group_2:basic set command

    command.   On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command

      command.   On (0xFF) or Off (0x00) to its associated group.

Support for Over temperature protection

ZW97 support Over temperature protection,When the temperature is greater than 105 degrees Celsius, the Heat Alarm signal is sent out
Notification Type : Heat  Alarm  0x04 .  Event :Overheat detected  0x02

Restoring Factory Defaults

ZW97 is removed from the network and will be restored to the factory setting

All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.

MANUAL RESET

 ---Power off ZW97

 ---keep holding the PROG button

 ---Power on,Press and keep holding the PROG button for no less than 10 seconds.

Remark : All the setting and data will be permanently deleted.

      When the output of the ZW97 Enpoint2 socket is changed, On (0xFF) or Off (0x00). The ZW97 will automatically send out a related

   When the output of the ZW97 Enpoint1 socket is changed, On (0xFF) or Off (0x00). The ZW97 will automatically send out a related

Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.