Warranty/ Disclaimer

EVACUAID LTD WARRANTS YOUR EVACUAID TO BE FREE FROM 

DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF 

TWO (2) YEARS FROM THE DATE OF PURCHASE. THE GUARANTEE 

APPLIES PROVIDED THAT THE INSTRUCTIONS ARE FOLLOWED. 

DEFECTIVE PRODUCTS SHOULD BE RETURNED TO THE PLACE OF 

PURCHASE. BATTERIES ARE NOT COVERED BY THIS WARRANTY.

THE MANUFACTURER IS NOT LIABLE FOR PERSONAL OR MATERIAL 

DAMAGES OR OTHER DAMAGE DIRECTLY OR INDIRECTLY 

CAUSED BY FIRE OR OTHER DISASTERS. ALL GUARANTEES OR 

WARRANTIES, EXPRESSED OR IMPLIED, IS STRICTLY LIMITED 

TO REPAIRING THE PRODUCT OR RECPLACING DAMAGED 

PRODUCT WITH NEW PRODUCT OR EQUIVALENT ITS VALUE. 

MANUFACTURER’S LIABILITY SHALL UNDER ANY CONDITIONS 

INCLUDING PRODUCT MALFUNCTION BE LIMITED TO PRODUCT 

PURCHASING PRICE. EVACUAID EMERGENCY BRACELET SHALL 

IN NO EVENT REPLACE REAL ESTATE INSURANCE, INJURY 

INSURANCE, DISABILITY INSURANCE, LIFE INSURANCE, OR 

OTHER INSURANCE. LIABILITY FOR SUCH INSURANCE IS EVERY 

CUSTOMER’S OWN RESPONSIBILITY.

Battery Change

It is recommended to use the SAFT LS 14500 or Tadiran SL760iXtra 

Contact your nearest distributor regarding alternative batteries.

In case of battery change the lid must be fixed with a 0.20 to 0.30 Nm 

of torque to ensure the tightness factor of IP67.

** 

Lithium batteries often have a lower voltage when first used, 

because they require a small surge to activate batteries fully. This does 

not affect performance, and batteries are kept fresh due to a small 

surge every 8 seconds when they are inserted. However, this affects 

the battery test when batteries are newly inserted, as voltage testing 

may show a low charge even if the batteries are in fact at full capacity.

Therefore, if batteries are newly inserted but not fully refreshed, the 

battery check will show a full charge, but will signify low voltage by 

giving red blinks every 2s for 2 minutes after testing. The batteries are 

refreshed after 2-7 days of being inserted, and battery check will then 

function as normal. However, if the inserted batteries are dead or near 

dead, this will only be signified 2-7 days after batteries are inserted. If 

the batteries were partially charged, the software estimation between 

5-100% will be meaningless.

Care and Maintenance

Evacuaid PRO Emergency Bracelet is maintenance free and has no 

need for specific maintenance. Note otherwise the following points:

· 

In case of strong soiling the device may be rinsed with cold water. 

If necessary, use a sponge to wash off.

· 

 Wipe the bracelet with a cloth.

Technical Specifications

Housing material: Overmoulded polycarbonate, 2K

Ingress protection: IP67

Alarm volume: 90dB (A) within a 3 meter range

Operating time: See included matrix

Dimensions: 83 x 69 x 32 mm [H x W x D]
CE marking and tests: EMC, EN 61000-6-2, EN 61000-6-3
FCC CFR 47 Part 15 : 2008

Disposal of the emergency bracelet

As of August 2005 EU regulations are applied 

for disposal of electronic and electrical 

appliances, laid down in EU policy 2002/96/EU 

and relevant national legislation, which applies 
to this appliance.

 

Evacuaid PRO

Emergency Bracelet Manual - Model 201

www.evacuaid.com

Manufacturer: 

Evacuaid AS

Gaustadalleen 21, Oslo Innovation Centre

0349 Oslo

Norge/Norway

Battery life and Service Concept

Remaining %

75 - 100 %

Estimated remaining hours

EM / MEM/ PSAM *

Battery testing

When the unit is deactivated, pressing the alarm button for 6 seconds initiates a battery check. 

This gives a software estimation of remaining capacity when batteries are between 100%-5% 

capacity. The top signal LEDs will flash according to the table below. Due to the voltage profile 

of lithium batteries the estimation is done by software monitoring, so only specified batteries 

must be used and fully charged for estimation between 5%-100% to be meaningfull.

If the capacity is 5% and below this will be indicated by 4 red flashes, and a continuous red 

flash every 2-8 seconds until batteries are replaced. The check for below 5% is done through 

voltage check, and is also performed after every use. When this is indicated, batteries must be 

replaced immediately.

Blink sequence 

when testing

50 - 75 %

25 - 50 %

10 - 25%

< 10 %

+ continuous red 

blinks every 2 - 8 

seconds

+ red blinks every 2 

s for 2 minutes

> 34 / 15 / 195

> 21 / 9 / 115

>10 / 4 / 50

> 4 / 1,5 / 17  

We recommend changing batteries

< 4 / 1,5 / 17 

Batteries should be  replaced 

< 2 / 0,7 /  6 

Batteries must be replaced, unit 

can cease to function at any time

New batteries not yet refreshed**

* EM = Evacuation Mode  MEM = Manual Emergency Mode  PSAM = Power Save Alarm Mode