DOWN UNDER
SERIES
14
POWER CONSUMPTION:
The engineering of this refrigeration system was done in-house here at Evakool, the system
is very well balanced incorporating extremely efficient rollbond evaporators with an air
cooled copper and aluminum finned condenser and the right amount of insulation to
give perfect cooling and maximum literage in the fridge compartments . We are extremely
happy with the performance of the refrigerator with all of our Australian made fridges
being true tropical rated .
DU47 Down Under 47 Litre - Climate Class ‘T’ Rated
Ambient
Temperature
Speed
Voltage
Fridge
Temp Set
Freezer
Temp Set
Amps consumed
per hour
24°C
ECO
12 .8 Volts
-16°C
1 .5
32°C
ECO
12 .8 Volts
-16°C
1 .95
38°C
ECO
12 .8 Volts
-16°C
2 .38
43°C
ECO
12 .8 Volts
-16°C
2 .97
24°C
MAX
12 .8 Volts
-16°C
1 .56
32°C
MAX
12 .8 Volts
-16°C
2 .11
38°C
MAX
12 .8 Volts
-16°C
2 .55
43°C
MAX
12 .8 Volts
-16°C
3 .27
24°C
ECO
12 .8 Volts
2°C
0 .7
32°C
ECO
12 .8 Volts
2°C
1
38°C
ECO
12 .8 Volts
2°C
1 .32
43°C
ECO
12 .8 Volts
2°C
1 .64
24°C
MAX
12 .8 Volts
2°C
0 .73
32°C
MAX
12 .8 Volts
2°C
1 .08
38°C
MAX
12 .8 Volts
2°C
1 .4
43°C
MAX
12 .8 Volts
2°C
1 .76
Test Conditions:
12.8V DC. Controlled test room. Set ambient temperatures. 24hr test period.
Fridge remained closed. No product inside. Fridge 2°C. Freezer -16°C.
Summary of Contents for DOWN UNDER Series
Page 1: ...SERVICE MANUAL FOR MODEL DU47 SZ DOWN UNDER SERIES ...
Page 2: ......
Page 20: ...DOWN UNDER SERIES 20 5 Product Drawings DU47 SZ External Dimensions ...
Page 21: ...DOWN UNDER SERIES 21 DU47 SZ Wiring Display ...
Page 23: ......
Page 24: ...For Service and Warranty support contact Evakool T 1300 385 665 EVKOOL E warranty evakool com ...