DOWN UNDER
SERIES
19
• Leave on main positive and negative .
• Remove all other wires including fan and bridge out terminal’s “C” and “T” .
E4 minimum speed issue:
Possible cause – overloaded fridge, module issue, worn or
tight bearings in compressor .
• If you have a second module (that’s known to be good) try it on the compressor to
confirm if compressor is seized or not .
• Let unit cool down and re-try .
Note:
Very rarely will you get a E4 error. More than likely end up with an E3 issue.
E5 Overheating issue:
Probable cause - fan has stopped, condenser is blocked with fluff,
vents are blocked/obstructed, or no ventilation to the fridge .
• Remove the back cover and check if fan has stopped or if the fan is still running .
• Check the condenser to see if blocked . To do this, turn off fridge, stand fridge on its end
to access the base, there is a small inspection panel, remove panel and inspect the back
section of the condenser . If blocked, remove the fan and blow compressed air from the
front of the condenser to remove fluff build up . Replace inspection plate, and test .
• Ask customer how the fridge is installed, if you find on your bench no fault found it may
be due to the installation .
Important:
Many caravans and camper trailer manufacturers are building “dust free” vans
many of these have little to no ventilation and fridges are cooking in their own heat.
Check out our service bulletin on Cross Flow Ventilation: https://www.evakool.com.au/
SSP%20Applications/NetSuite%20Inc.%20-%20SCA%202020.1/Development/img/Cross%20
Flow%20Ventilation.pdf
Summary of Contents for DOWN UNDER Series
Page 1: ...SERVICE MANUAL FOR MODEL DU47 SZ DOWN UNDER SERIES ...
Page 2: ......
Page 20: ...DOWN UNDER SERIES 20 5 Product Drawings DU47 SZ External Dimensions ...
Page 21: ...DOWN UNDER SERIES 21 DU47 SZ Wiring Display ...
Page 23: ......
Page 24: ...For Service and Warranty support contact Evakool T 1300 385 665 EVKOOL E warranty evakool com ...