EVCO S.p.A.
Vcolor 869/879
| Installer manual ver. 2.2 | Code 144VC869E214
page 21 of 94
5
USER INTERFACE
5.1
Initial information
The interface has the following operating modes:
-
“off” (no power to the device);
-
“stand-by” (the device is powered but switched off);
-
“on” (the device is powered, switched on and awaiting start-up of an operating cycle);
-
“run” (the device is powered, switched on and running an operating cycle).
Terminology: “switch on the device” means moving from “stand-by” to “on” mode and “switch off the device” means
moving from “on” to “stand-by” mode.
If the power supply fails during “stand-by” or “on” mode, when power is restored the device will return to the mode set
before the failure.
If the power supply fails during “run” mode, when power is restored the device will operate as follows:
-
if blast chilling or blast-freezing was in progress, the cycle will resume, taking into account the duration of
the power loss;
-
if a conservation cycle was running, this will continue using the same settings;
-
if a proofing or slow cooking cycle was running, the cycle will continue where it left off.
5.2
Initial switch-on
Connect the power supply to the device: if parameter E9 is set at 1, the device will show the splash screen as defined
in the customized graphical skin; if the parameter is set at 0, a system loading screen will be shown:
E9=0
E9=1