8.6
Ionizer
The ionizer is an alternative function to the UV lamp function, inherent in the sterilization cycle.
Based on parameter E17, the type of sterilization present in the device will be defined and consequently the relative icon
will be displayed.
The digital output is the same for both options.
If E17 is configured for the UV lamp, the cycle remains the same as the existing one with the cycle management from
the special cycles menu.
If E17 is configured for the ionizer, the cycle will work as follows:
This key can activate the ionizer (if the cycle has been started and if the cell temperature is greater than 0 ° C) in the
following operations:
- blast chilling (see example)
- blast freezing
- defrosting
- slow cooking
- cold storing
If the ionizer is active but the cell temperature drops below 0 ° C, the ionizer is switched off (button icon disabled) and
remains in this condition even if the cell temperature rises above 0 ° C (in this second case however the user can
reactivate the ionizer manually by key).
If the ionizer is active but the cell temperature drops below 0 ° C, the ionizer is switched off (button icon disabled) and
remains in this condition even if the cell temperature rises above 0 ° C (in this second case however the user can
reactivate the ionizer manually by key).
The operation of the ionizer, in the passage from cycle to storage, is defined by parameter E18.