During storage, whether it has been activated automatically by parameter E18 or manually by key, the ionizer remains
on for the time defined by the new parameter E19.
If E19 = 0 it means that during storage it can never be activated (either automatically or manually by key).
8.7
Heating the needle probe
Pressing this area enables selection of a needle probe, or probes, heating cycle. The cycle can be run only if the door is
open.
This cycle can also be run automatically if the
key is pressed during conservation, following a blast
chilling/defrosting cycle.
The needle probe heating output is activated at maximum for the time set by parameter u8 or until the temperature
indicated by the needle probe has reached that set by parameter u7.
At the end of heating, the buzzer sounds.
Heating can be stopped by pressing the
key.
8.8
Drying
Pressing this area enables selection of a drying cycle.