EVCO S.p.A.
Vcolor 869/879
| Installer manual ver. 2.2 | Code 144VC869E214
page 52 of 94
F40
fan speed
Two areas at the bottom of the screen make it possible to add a subsequent blast chilling/blast-freezing phase
and a product holding/conservation phase
.
For blast chilling or blast-freezing, the pre-settings are those for the cycle, whereas the following parameters are used
to set up a holding or conservation phase:
rH13
cabinet set point for holding phase
rU10
% humidity in holding
F41
fan speed
If a holding phase has been enabled following a slow cooking cycle, this will be activated at the set temperature and
humidity and it will have an indefinite duration. If blast chilling or blast-freezing has been enabled, this will be performed
according to the procedures for the cycle in question (blast chilling/blast-freezing and moving on automatically to
conservation).
Slow c holding Slow cblast-ch holding