User interface-control module communication error.
To correct
-
Check the user interface-control module connection.
Main consequences
-
Any cycle underway will be terminated and it will not be possible to start one up.
BOARD
COMPATIBILITY
User interface-control module compatibility error.
To correct
- Check that the user interface and the control module are compatible.
Main consequences
- Any cycle underway will be terminated and it will not be possible to start one up.
NEEDLE PROBE
Needle probe alarm (all the needle probe sensors enabled are in alarm status)
To correct
-
The same as for the cabinet probe error but with reference to all the needle probes.
Main consequences
-
Any temperature controlled cycle will be interrupted
POWER FAILURE
Power failure alarm (HACCP alarm).
To correct
-
Check the device-power supply connection.
Main consequences:
-
The device will memorise the alarm.
-
Any cycle underway will resume when power is restored.
-
The alarm output will be activated.
SANITATION
PROBE
INSERTION
Sanitation alarm.
To correct
-
Check that the needle probe has been correctly inserted and check the value of
parameters r17 and r18.
Main consequences
-
The sanitation cycle will be interrupted.
SANITATION
DURATION
Alarm indicating that sanitation has not been completed within the maximum duration (HACCP
alarm).
To correct
-
Check the value of parameter r23
Main consequences
-
The device will memorise the alarm.
-
The cycle underway will be interrupted.
-
The alarm output will be activated.
CONDENSER
OVERHEAT
Condenser overheat alarm.
To correct
-
Check the condenser temperature.
-
Check the value of parameter C6.
Main consequences
-
The condenser fan will be switched on.
-
The alarm output will be activated.