EVCO S.p.A.
Vcolor 869/879
| Installer manual ver. 2.2 | Code 144VC869E214
page 91 of 94
Digital outputs
9, electro-mechanical relays The maximum permitted current on loads
3 and 4 is 10 A, on load K1 is 20 A (see the electrical circuit diagram).
The relays do not manage LED and fluorescent lamps
Compressor relay: 30 A SPST res. @ 250 VAC.
Defrost relay: 8 A SPST res. @ 250 VAC.
Evaporator fan relay: 8 A SPST res. @ 250 VAC.
Condenser fan relay: 8 A SPST res. @ 250 VAC.
Door heater relay: 8 A SPDT res. @ 250 VAC.
Door heater relay: 16 A SPST res. @ 250 VAC.
Auxiliary relay 1: 16 A SPST res. @ 250 VAC.
Auxiliary relay 2: 8 A SPST res. @ 250 VAC.
Auxiliary relay 3: 8 A SPST res. @ 250 VAC.
Type 1 or Type 2 Actions
Type 1.
Additional features of Type 1 or Type 2
actions
C.
Displays
7 or 5-inch capacitive TFT touch-screen graphic display, 65K colours,
800 x 480 pixel resolution. The presence of point defects on the display
falls within the tolerance limits as provided by applicable standards.
Alarm buzzer
Built-in.
Communications ports
- 1 RS-485 MODBUS port
- 1 USB port