8
EN
temperature to " " . Do not disconnect the power. Thus the temperature of the water
in the tank is maintained at about 9 °C. Should you choose to disconnect the power,
the water heater should be thoroughly drained before the onset of freezing
conditions. Water from the heater is drained through the inlet/outlet pipe of the
heater.
The exterior of the water heater may be cleaned with a mild detergent solution. Do
not use solvents and abrasive cleaners.
Regular preventive maintenance inspections ensure faultless performance and long
life of your heater. The first of these inspections should be carried out by the
authorised maintenance service provider about 36 months from the date of
installation in order to check the wear of the protective anticorrosion anode and
remove any build-up of calcium and lime as required. The build-up of calcium and
lime in the water heater depends on the quality, quantity and temperature of water
flowing through the heater. The maintenance service provider shall also issue a
condition report and recommend the approximate date of the next inspection.
In the event of the heater breaking down, you are kindly requested to contact
the authorised maintenance service provider located closest to you. Please do
not attempt to carry out any repairs yourself.
TECHNICAL PROPERTIES OF THE
APPLIANCE
1)
EU Regulation 812/2013; EN 50440
2) EN 50440
WE RESERVE THE RIGHT TO MAKE CHANGES THAT DO NOT IMPAIR THE
FUNCTIONALITY OF THE DEVICE.
Type
GT 5 O
GT 5 U
GT 10 O GT 10 U GT 15 O GT 15 U
Declared load profile
XXS
XXS
XXS
XXS
XXS
XXS
Energy efficiency class
1)
A
A
A
A
A
A
Water heating energy efficiency
(ƞwh)
1)
35,9
35,2
36,3
35,2
36,1
35,3
[%]
Annual electricity consumption
1)
514
525
508
524
510
523
[kWh]
Daily electricity consumption
2)
2,410
2,480
2,377
2,461
2,391
2,465
[kWh]
Thermostat temperature settings
e
Value of "smart"
0
0
0
0
0
0
Volume
6,2
6,6
9,8
9,9
14,8
14,9
[l]
Rated pressure
0,6 (6) / 0,9 (9) / 1,0 (10)
[[MPa
(bar)]
Weight / Filled with water
6,8 / 11,8
8 / 18
11 / 26
[kg]
Anticorrosion protection of the tank
Enamelled / Mg anode
Power of electrical heater
2000
[W]
Voltage
230
[V~]
Protection class
I
Degree of protection
IP24
Heating time from 10
°C
to
65 °C
11
20
29
[min]
Packaging dimensions
300x300x440
300x400x530
350x400x530
[mm]