Even-GLO™ Series GA301
Page 42
October-28-15
Maintenance & Troubleshooting Instructions
c.
Remove the Gas Hose Assembly from the Pole to inspect and Leak Test
the
entire hose and all connections
. Repair / replace as required.
2.
Check condition of the Burner, especially the integrity of the flame screen.
3.
Inspect condition of spark and sense electrode. Check for cracks in ceramic
insulators or excessive corrosion.
4.
Inspect condition of high tension lead to spark rod
Troubleshooting instructions for models GA301-M & GA301-MP:
1.
No gas supply at burner:
•
Ensure manual shut off valve is in proper position
•
Ensure there is pressure and flow at inlet to gas valve.
2.
No spark:
•
Ensure battery in ignition module is operating.
•
Ensure spark electrode assembly is grounded and there are no cracks in
ceramic insulator.
•
Ensure the gap (spark gap) between Pilot and Spark Ignitor electrode is 1/8” –
3/16” (3mm – 4.5mm) as per picture below.