Even-
GLO™ Series GA301
Page 18
Oct. 4, 2018
Portable Models (GA301M & GA301MP)
Secure Pole and Regulator Bracket to Bottom Base
a) Flip Base right side up,
remove Portable Base Housing
and place Pole on the
4 threads of the Elevator Bolts.
b) Line up Pole Flange indication dot with the Bottom Base indication dot. Slide
bottom housing into place as shown.
c) Unplug the quick disconnect from the one side of the supply hose and feed hose
through the inside of the bottom housing until it reaches the other end of the
hose. Plug quick disconnect back in to the outer side of the hose once done.
d)
Connect the supply hose with NG Regulator w/Mounting Plate and position &
secure to pole flange using 2 nuts with a 9/16 socket to tighten.