Even-
GLO™ Series GA301
Page 38
Oct. 4, 2018
Lighting instructions for models GA301, GA301-H & GA301-T:
1. Open manual gas supply valve (ensure gas supply lines have been purged).
2. Turn on switch to energize electric supply.
3. The electronic control module will time out 45 sec.
4. The gas valve will open and ignition spark will commence and continue for 15
sec.
5. If flame starts a
nd “is detected”, flame will continue until turned off.
6.
If flow does not start, the gas valve will close after 15 sec. A “wait’ period
commences and lasts about 30 sec. and a second trial for combustion
commences. The electronic control will attempt three trials for ignition before
locking out for about one hour at which time it will automatically try again.
Electronic control of heater can be re-set by de-energizing and re-energizing
electric power.
Shut Down instructions for models GA301, GA301-H & GA301-T:
1. Turn off power to electronic control.
2. For longer periods of shut down, also close manual gas supply valve.
Lighting instructions for models GA301-M & GA301-MP:
1.
Open manual gas supply valve (ensure gas supply lines have been purged).
2.
Push and turn the ignition knob counter-clockwise from the OFF
position to the
PILOT position lightning symbol.
To start the gas flow and sparking, push the
knob inwards.
Keep pressing until the pilot is lit and stays lit (for
approximately 30-45 seconds to heat up the thermocouple) and then
release the pressure from the knob
. If you have warmed up the thermocouple
enough, when you release the pressure from the ignition knob the main burner
will automatically light. If it does not, try igniting the pilot again but waiting a
longer interval before releasing knob.
3.
Note:
When using the heater with a fresh fuel supply, pilot may take some
time to light because the line needs to purge all of the air out in the line
first
.
4.
Adjust the heat output by rotating the Temperature Control Knob counter-
clockwise to increase output, clockwise to lower the output.