Maintennce and Trouble Shooting
Trouble Shooting
1.
No gas supply at burner:
•
Ensure manual shut off valve is in proper position
•
Ensure there is pressure and flow at inlet to gas valve.
•
Ensure LP-Gas Cylinder has fuel in it.
2.
No spark:
•
Ensure battery in ignition module is operating.
•
Ensure spark electrode assembly is grounded and there are no cracks in ceramic insulator.
•
Ensure the gap (spark gap) between Pilot and Spark Ignitor electrode is 1/8” – 3/16” (3mm –
4.5mm) as per picture below.
3.
Flame lights but will not stay lit:
•
Be sure to hold knob in for one minute or longer to allow sensor to get hot.
•
Ensure there is no overpowering wind.
•
Ensure sense electrode is not corroded, is not grounded or has a cracked insulator. Electrode
position is radially across face of burner.
Replacement Parts
•
Use only manufacturer recommended replacement parts.
•
For a complete list of replacement parts contact your dealer.
1/8”
(3mm)
Gap
alfresco-heating.com
888-Warm-Glo