__________________________________________________________________________________________________________________
Series GA201-M2
19
LT126 June 2021
OPERATING INSTRUCTIONS
Lighting
1. Open the propane cylinder valve.
2. Push and turn the ignition knob counter-clockwise from the OFF
position to the PILOT position
(lightening
symbol). To start the gas flow and sparking, push the knob inwards.
Keep pressing until the pilot is lit and
stays lit (for approximately 30-45 seconds to heat up the thermocouple) and then release the pressure
from the knob
. If you have warmed up the thermocouple enough, when you release the pressure from the
ignition knob, the main burner will automatically light. If it does not, try igniting the pilot again, but waiting a longer
interval before releasing the knob.
Note: When using the heater with a fresh fuel supply, pilot may take some time to light because the light
needs to purge all the air out of the line first.
Figure 15: Location of Ignition Knob and Temperature Control Knob
CAUTION
Heater will produce smoke the first time it is lit. This is normal.
DO NOT light the heater in an enclosed area.
Adjusting Temperature
Adjust the heat output by rotating the Temperature Control Knob counter-clockwise to increase the output, clockwise
to lower the output.
Shutdown
1. Turn the ignition knob clockwise into the OFF position to turn off the gas flow and extinguish the burner flame.
2. Turn propane cylinder valve clockwise to OFF position when heater is not in use.
WARNING
Improper Lighting, Shutting Down can cause injury, death, or property damage. Read the Lighting and
Shutting Down instructions thoroughly before operating or servicing this equipment.