Troubleshooting
No Gas Supply at Burner
•
Ensure manual shut off valve is in proper position.
•
Ensure there is pressure and flow at inlet to gas valve.
•
Ensure propane gas cylinder has fuel in it.
•
When using the heater with a fresh fuel supply, pilot may take some time to light because the light needs to
purge all the air out of the line first.
No Spark
•
Ensure the battery in ignition module is operating.
•
Ensure spark electrode assembly is grounded and there are no cracks in the ceramic insulator.
•
Ensure the spark gap between the pilot and spark ignitor is 1/8”-3/16” (3-4.5mm) as per picture below:
Figure 18: Proper Spark Gap
Flame Lights but Will Not Stay Lit
•
Be sure to hold pilot knob in for one minute or longer to allow sensor to get hot.
•
Ensure there is no overpowering wind.
•
Ensure sense electrode is not corroded, is not grounded, and does not have a cracked insulator.