Table of Configuration Variables
BD600+ Profanity Delay
Chapter 3 Configuration
Page 23
Document Version 2.1
Note: Full descriptions of the selectable values are available in pages following this table. Some of
these values are specific to either the BD600+ or .
4 Character
Identifier
Description
Units
Range of Values
Default
Value
CONF
Start of Configuration Mode
This selection has no configurable
value. It indicates entry into
con-
figuration
mode
1 ON
Online Parameters
RUN
Run Mode
Selects the mode the unit goes into
from
bypass
. Select
MPD
to enable
precision fixed delay
mode
LIVE REB WFS MPD
LIVE
POWP
Power-Up Mode
Selects which mode the unit goes
to after power-up.
mode
INLN BYP PREV
BYP
BYP
Bypass Mode
Selects the
bypass
mode
mode
RLA DSP MUTE
RLA
DISP
Display Digits
Selects the number of digits after
the decimal point in
profanity de-
lay
mode
# of digits
OFF 0 1.1 2.22
2.22
LITE
Display Brightness
Sets the display brightness
level
LOW MID HIGH
MID
PASS
Password
Allows a password to be selected
which would limit access to the
configuration
mode
button
NONE BYP WFS WAE
REB RT0 SNEZ
DUMP
NONE
JING
Jingle File
The name of the current jingle file
name
OFF ONE TWO THRE
FOUR
OFF
LOCK
Lock Front Panel
Disable the front panel keys
NO YES
NO
SHOW
Delay Display Type
Show delay used or delay free
USED FREE
USED
2 TI
Time Parameters
DLAY
Delay Length
Maximum length to which the pro-
fanity delay will rebuild
seconds
MPD 4.0 6.0 8.0
………..
40.0 60.0 80.0
8.0