Trigger Mapping
Here you assign 11 functions to be triggered, depending on the value of the CV In
when the trigger comes in. The incoming voltage determines which function will
be triggered, depending on which range it falls in. For example, if the CV In range
is set to 0-5V, then whatever is assigned to one of Num 1-11 will be triggered
when the voltage is in the range shown in the table below.
Num 1:
0-0.45 V
Num 2:
0.45-0.91 V
Num 3:
0.91-1.36 V
Num 4:
1.36-1.82 V
Num 5:
1.82-2.27 V
Num 6:
2.27-2.73 V
Num 7:
2.73-3.18 V
Num 8:
3.18-3.64 V
Num 9:
3.64-4.09 V
Num 10:
4.09-4.55 V
Num 11:
4.55-5 V
There is a comprehensive list of functions of on/off type functions available here,
including changes of scale, key, chord, and sequencer operation.
CV IN Y
Menu is the same as for CV In X.
Default (relevant settings):
Linking=”Linked (Gate/CV)”
CV Function=”Pitch Bend”
CV IN Z
Menu is the same as for CV In X.
Default (relevant settings):
Linking=”Linked (Gate/CV)”
CV Function=”Transpose”
MIDI
Input Channel
(1-16, Omni*)
Output Channel
(1*-16)
Output Velocity
(64
*
) (1-127)
43