SINLINE series UPS – Instruction Manual
2010/01/26
www.ever.eu
26
TECHNICAL PARAMETERS – Rack Model
PARAMETERS /
UPS TYPE
SINLINE 1200
Rack
SINLINE 1600
Rack
SINLINE 2000
Rack
SINLINE 3000
Rack
Output power
1)
1200VA/
780W
1600VA/
1040W
2000VA/
1350W
3000VA/
1950W
Working environment
Office or industrial rooms with low level of pollution
Operating temperature
2)
+10 ÷ +35 °C
Storage temperature
0 ÷ +45 °C
Relative humidity for operation
20 ÷ 80 % (without condensation)
Relative humidity for storage
20 ÷ 95 % (without condensation)
Altitude (above sea level)
3)
up to 1000 m
Maximum length of outgoing cables
< 10 m
MAINS OPERATION MODE
Input voltage
4)
~160 ÷ 264 V (~145 ÷ 280 V) ± 2 %
Frequency of input voltage
45 ÷ 55 Hz ± 1 Hz
Range of output voltage
4)
~184 ÷ 264 V (~167 ÷ 280 V) ± 2 %
Switching thresholds: Mains – ups
4)
~160 V / ~264 V (~145V / ~280 V) ± 2 %
Shape of output voltage
Sinus
Filtering of output voltage
Noise filter RFI/EMI varistor damper
Time to switch to UPS
<3 ms
BATTERY MODULE (BATTERY) OPERATION MODE
Output voltage (effective value)
~230 V ± 5 %
Shape of output voltage
Sinus
Switching thresholds: ups – mains
4)
~165 V / ~259 V (~150 V / ~275 V) ± 2 %
Frequency of output voltage
50 Hz ± 1 Hz
Filtering of output voltage
LC
Shorting safeguard
Electronic
Overload protection
Electronic
Time to switch back to mains operation
0 ms
Support time 100%/80%/50%P
max
4,5/6/10 min
4/5/8 min
4/5/9 min
3/4/8 min
Battery
2 x 7 Ah
3 x 5 Ah
4 x 5 Ah
4 x 7 Ah
Maximum charging time
7 h
5 h
5 h
7 h
MECHANICAL PARAMETERS
Dimensions
2U x 19” × 320
3U x 19” × 400
3U x 19” × 400
3U x 19” × 400
Weight
20 kg
25 kg
32.5 kg
35 kg
EQUIPMENT
Number of outlet sockets
6 x IEC320 C13
Signalling
Acoustic and visual (LEDs)
Circuit breaker
10 A
10 A
15 A
15 A
Communication interface
RS 232
Note: The manufacturer reserves the right to change the abovementioned parameters without notice.
Notes:
1)
For normal operation of the UPS the load connected to its output should not exceed 80% of value indicated in the table.
Reserve power is essential to ensure continuous operation of connected devices in case of momentary rushes in load
current.
2)
Continued exposure of the UPS to the temperature of the surrounding exc25°C will shorten the life of batteries.
3)
If the altitude above sea level increases beyond the provided limit the permitted load power of the batter battery module
decreases.
4)
The user may change the switching thresholds by setting standard or enhanced thresholds, respectively (provided in
parentheses).