background image

2

maintenance float mode.

IMPORTANT

 

SAFETY

 

INSTRUCTIONS

Please

 

read

 

this

 

manual

 

and

 

follow

 

the

 

instructions

 

carefully

before

 

using

 

the

 

charger.

WARNING

The

 

EP12M248

charger

 

is

 

designed

 

to

 

charge

 

12V

 

lead-acid

batteries

 

from

 

6Ah

 

to

 

8

0Ah

.

 

Check

 

battery

 

manufacturer

 

specifications

 

before

 

using

 

this

 

charger.

 

Explosive

 

gases

 

may

 

escape

 

from

 

the

 

battery

 

during

 

charging.

Provide

 

ventilation

 

to

 

prevent

 

flames

 

and

 

sparks.

Do

 

not

 

expose

 

charger

 

to

 

rain,

 

snow

 

or

 

liquids.

Battery

 

acid

 

is

 

corrosive.

 

Rinse

 

immediately

 

with

 

water

 

if

 

acid

 

comes

 

into

 

contact

 

with

 

skin

 

or

 

eyes.

Do

 

not

 

charge

 

a

 

frozen

 

or

 

damaged

 

battery.

Do

 

not

 

charge

 

non-rechargeable

 

batteries.

Do

 

not

 

place

 

the

 

charger

 

on

 

the

 

battery

 

while

 

charging.

Be

 

extra

 

cautious

 

to

 

reduce

 

risk

 

of

 

dropping

 

a

 

metal

 

tool

 

onto

 

battery.

 

It

 

might

 

spark

 

or

 

short-circuit

 

battery

 

or

 

other

 

electrical

 

part

 

that

 

may

 

cause

 

explosion.

When

 

working

 

with

 

a

 

lead-acid

 

battery,

 

remove

 

personal

 

metal

 

items

such

 

as

 

rings,

 

bracelets,

 

necklaces,

 

watch…

Do

 

not

 

smoke

 

or

 

allow

 

a

 

spark

 

or

 

flame

 

while

 

charging.

In

 

order

 

to

 

reduce

 

risk

 

of

 

electric

 

shock,

 

unplug

 

charger

 

from

 

AC

 

outlet

 

before

 

doing

 

any

 

maintenance

 

or

 

cleaning.

Not

 

for

 

use

 

by

 

children

 

or

 

by

 

anyone

 

who

 

is

 

unable

 

to

 

follow

 

instructions

 

of

 

this

 

manual,

 

unless

 

they

 

are

 

supervised

 

by

 

an

 

adult

 

to

 

ensure

 

the

 

proper

 

use

 

of

 

charger.

MAINTENANCE:

The

 

case

 

should

 

be

 

cleaned

 

occasionally.

 

Disconnect

 

from

 

the

 

power

while

 

cleaning.

If

 

the

 

power

 

cord

 

is

 

damaged,

 

or

 

if

 

there

 

are

 

any

 

signs

 

of

 

physical

damage,

 

the

 

charger

 

must

 

be

 

serviced

 

by

 

a

 

qualified

 

technician.

MAIN

 

FEATURES:

 

High

 

efficiency

 

(>85%).

 

Selectable

 

charging

 

rates

 

to

 

suit

 

battery

 

capacity.

 

Selectable

 

battery

 

type.

 

Temperature

 

self-compensation:

 

Charging

 

voltage

 

adapts

 

to

temperature

 

to

 

prevent

 

over

 

or

 

under

 

battery

 

charging.

 

Capable

 

of

 

recharging

 

severely

 

discharged

 

or

 

heavily

 

sulfated

battery.

 

Reverse

 

polarity

 

protection,

 

short

 

circuit

 

protection,

 

sparks

 

free

contact.

 

Ultra

 

low

 

input

 

power

 

consumption

 

while

 

in

 

standby

 

mode.

 

Ease

 

of

 

use.

 

Clear

 

charging

 

status

 

display.

 

Full

 

microprocessor

 

controlled.

 

Does

 

not

 

over

 

charge

 

your

 

battery

 

even

 

if

 

it

 

is

 

kept

 

connected

 

in

Summary of Contents for EP12M248L

Page 1: ...1 EP12M248L 7 Stage Automatic Smart Battery Charger Desulphuration Maintainer 12V 2 4 8A FOR AGM GELANDWETBATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS ...

Page 2: ...s bracelets necklaces watch Do not smoke or allow a spark or flame while charging In order to reduce risk of electric shock unplug charger from AC outlet before doing any maintenance or cleaning Not for use by children or by anyone who is unable to follow instructions of this manual unless they are supervised by an adult to ensure the proper use of charger MAINTENANCE The case should be cleaned oc...

Page 3: ... charging time for each charging stage In the event it is wired to recharge a larger than recommended battery charger will stop charging after maximum stage recommended time and the RED LED will be FLASH slowly At this point Battery must be disconnected REVERSE POLARITY Charger has reverse battery protection Red LED ON while output leads are connected backwards Disconnect and correct connection to...

Page 4: ...led VRLA Calcium batteries 14 7V 13 6V 15V TECHNICALSPECIFICATIONS Model EP12M248L Type Smart Automatic Input ULVersion Input CE 12V 2 4 8A 0 5V 2 0V Input Power W Load 34 126W Input Power No Load 0 3 0 8W Compensated m m L W H 8 3 5 2 in 1 87LB Approval FCC CE n o i s r e V 220 240VAC 50 60Hz Net Weight Size Minimum Start Volt Temperature Output Volt No Load Output Current Output Voltage 30mV C 6...

Page 5: ...Red lead from the charger to the positive battery terminal Connect the Black lead from the charger to the negative battery terminal If battery is still in the vehicle determine if the vehicle is positively or negatively earthed If Negatively earthed Most Common First connect the Red battery charger lead to the Positive battery post and then connect the Black battery charger lead to the vehicle s c...

Page 6: ...will go into desulphation mode If the battery voltage does not exceed 9V after 6 hours of rejuvenation you will need to disconnect the battery and check its condition voltage rating or if it is connected to a load while charging Smart Charging Stages Desulphation 20 charging LED ON Engage high peak pulse for deep discharge or sulphated battery dissolve the lead sulphated crystal bring the electrol...

Page 7: ...your batteries it works at a safe level and ready for use Maintenance mode Full LED ON The program engages a special charging waveform and monitors the battery voltage variety if the battery voltage sinks the special pulses will keep the battery in optimal state if the battery voltage drops even lower the battery charger will switch into bulk charging The maintenance mode allows the charger to be ...

Page 8: ...LARGE LCD DISPLAY Convenient to read data in the process of your use real time feedback of battery status ...

Page 9: ...t is switched ON No DC Output Fault RED LED is ON Output is short circuited Reverse polarity connection to Battery Check DC connection between charger and battery and make sure they are not short circuiting Check that the crocodile clips ring terminals are connected to the correct polarity No Charging Current Fault RED LED is flashing Battery is severely sulphated Overheat protection mode Move bat...

Reviews: