background image

5

ELECTRICALPARTS:

AC power cord: 6 feet SPT-2 with UL plug

Output lead: 6 feet SPT-1 2X18AWG with insulated battery clamps.

ENVIRONMENTALCHARACTERISTICS:

Operating temperature range: 32 to 104° F

Storage temperature range: 10 to 170°F

Operating humidity range: 90% RH Max

ECO MODE:

If AC power is connected, and the battery is not connected, the charger

will automatically go into ECO mode. Input power draw in ECO mode is

less than 1.5W (0.04kWh per day).

Power consumption in maintenance mode is 0.05kWh per day

.

CHARGING INSTRUCTIONS:

STEP 1 - Pre Charge:

Battery & Electrolyte Level Check

Check the battery electrolyte level (Only for Flooded or WET
battery).

If necessary, remove the vent caps and add distilled water so the

levels are halfway between the upper and lower fill lines.

STEP

 

2

 

-

 

Connect

 

Charger

 

to

 

Battery

 

If

 

the

 

battery

 

is

 

out

 

of

 

the

 

vehicle

:

 

Connect

 

the

 

Red

 

lead

 

from

 

the

 

charger

 

to

 

the

 

positive

 

(+)

 

battery

terminal.

 

Connect

 

the

 

Black

 

lead

 

from

 

the

 

charger

 

to

 

the

 

negative

 

(-)

 

battery

terminal.

 

If

 

battery

 

is

 

still

 

in

 

the

 

vehicle

,

 

determine

 

if

 

the

 

vehicle

 

is

 

positively

or

 

negatively

 

earthed.

 

If

 

Negatively

 

earthed

 

(Most

 

Common)

 

 

First

 

connect

 

the

 

Red

 

(+)

 

battery

 

charger

 

lead

 

to

 

the

 

Positive

 

(+)

 

battery

 

post

 

and

 

then

 

connect

 

the

 

Black

 

(-)

 

battery

 

charger

 

lead

 

to

 

the

 

vehicle’s

 

chassis

 

and

 

away

 

from

 

the

 

fuel

 

line.

 

If

 

Positively

 

earthed

 

 

First

 

connect

 

the

 

Black

 

(-)

 

battery

 

charger

 

lead

 

to

 

the

 

Negative

 

(-)

 

battery

 

post

 

and

 

then

 

connect

 

the

 

Red

 

(+)

 

battery

 

charger

 

lead

 

to

 

the

 

Vehicle’s

 

chassis

 

and

 

far

 

away

 

from

 

the

 

fuel

 

line.

STEP

 

3

 

 

Connect

 

Charger

 

to

 

Power

 

(230V

 AC

)

 

Connect

 

the

 

battery

 

charger

 

to

 

AC

 

mains

 

powered

 

socket.

 

The

 

Charger

 

will

 

automatically

 

start

 

when

 

AC

 

power

 

is

 

connected

and

 

switched

 

on.

(Note:

 

If

 

the

 

Fault

 

Indicator

 

LED

 

illuminates

 

Red,

 

please

 

check

 

your

 

connections

 

as

 

it’s

 

likely

 

that

 

the

 

Positive

 

and

 

Negative

 

leads

 

are

 

reversed.

 

Refer

 

to

 

Trouble

 

Shooting

 

page

 

for

 

further

 

information)

Check the battery label - it must be 12V

Summary of Contents for EP12M248L

Page 1: ...1 EP12M248L 7 Stage Automatic Smart Battery Charger Desulphuration Maintainer 12V 2 4 8A FOR AGM GELANDWETBATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS ...

Page 2: ...s bracelets necklaces watch Do not smoke or allow a spark or flame while charging In order to reduce risk of electric shock unplug charger from AC outlet before doing any maintenance or cleaning Not for use by children or by anyone who is unable to follow instructions of this manual unless they are supervised by an adult to ensure the proper use of charger MAINTENANCE The case should be cleaned oc...

Page 3: ... charging time for each charging stage In the event it is wired to recharge a larger than recommended battery charger will stop charging after maximum stage recommended time and the RED LED will be FLASH slowly At this point Battery must be disconnected REVERSE POLARITY Charger has reverse battery protection Red LED ON while output leads are connected backwards Disconnect and correct connection to...

Page 4: ...led VRLA Calcium batteries 14 7V 13 6V 15V TECHNICALSPECIFICATIONS Model EP12M248L Type Smart Automatic Input ULVersion Input CE 12V 2 4 8A 0 5V 2 0V Input Power W Load 34 126W Input Power No Load 0 3 0 8W Compensated m m L W H 8 3 5 2 in 1 87LB Approval FCC CE n o i s r e V 220 240VAC 50 60Hz Net Weight Size Minimum Start Volt Temperature Output Volt No Load Output Current Output Voltage 30mV C 6...

Page 5: ...Red lead from the charger to the positive battery terminal Connect the Black lead from the charger to the negative battery terminal If battery is still in the vehicle determine if the vehicle is positively or negatively earthed If Negatively earthed Most Common First connect the Red battery charger lead to the Positive battery post and then connect the Black battery charger lead to the vehicle s c...

Page 6: ...will go into desulphation mode If the battery voltage does not exceed 9V after 6 hours of rejuvenation you will need to disconnect the battery and check its condition voltage rating or if it is connected to a load while charging Smart Charging Stages Desulphation 20 charging LED ON Engage high peak pulse for deep discharge or sulphated battery dissolve the lead sulphated crystal bring the electrol...

Page 7: ...your batteries it works at a safe level and ready for use Maintenance mode Full LED ON The program engages a special charging waveform and monitors the battery voltage variety if the battery voltage sinks the special pulses will keep the battery in optimal state if the battery voltage drops even lower the battery charger will switch into bulk charging The maintenance mode allows the charger to be ...

Page 8: ...LARGE LCD DISPLAY Convenient to read data in the process of your use real time feedback of battery status ...

Page 9: ...t is switched ON No DC Output Fault RED LED is ON Output is short circuited Reverse polarity connection to Battery Check DC connection between charger and battery and make sure they are not short circuiting Check that the crocodile clips ring terminals are connected to the correct polarity No Charging Current Fault RED LED is flashing Battery is severely sulphated Overheat protection mode Move bat...