7. Troubleshooting

 

Problem Possible 

Cause 

Correction 

Indicator or 

display does not 

light

 

• no power input 

• PCB main board damage

 

• check power cord connection 

• turn on power 

• replace new PCB main board

 

Cannot dispense

 

• foot pedal not plugged in properly 

• defective foot pedal 

• foot pedal port broken or loosen 

• Rotary Pump damage 

• check connection 

• foot pedal needs to be repaired or replaced

• remove the cover and check for broken or 

loosen 

• replace the Rotary Pump 

Inconsistent 

dispensing

 

• air bubbles in adhesive 

• dispensing needle not appropriate 

• dispensing needle clogged 

• Teflon Tube clogged or deformed 

• decrease vacuum setting and de-bubble 

the adhesive before filling 

• replace with different type of needle 

• replace needle 

• replace Teflon Tube 

 

 

8. Limited warranty

 

Ever Sharp warrants this product to the original purchaser for a period of one year from date of purchase to be free from 

material and workmanship defects but not normal wear-and-tear, abuse and faulty installation. Defective product or 

subassembly and components under warranty will be repaired or replaced (at Ever Sharp option) free of charge. Customer 

with defective product under warranty must contact the nearest Ever Sharp office or distributor to secure a return 

authorization prior to shipping the product to the assigned Ever Sharp authorized service center. For nearest Ever Sharp 

office or distributor contact information, please visit 

www.eversharp.com.tw

 or contact our stuff. Ever Sharp reserves the 

right to make engineering product changes without notice. 

 

 

Summary of Contents for ES2088

Page 1: ...itch 2 Hardware Setup a Connect the Power Cord on the back of the system and switch the power on Please make sure all the display and light indicator are working properly 110V 240V full voltage b Connect the Foot Pedal on the back of the system or Finger Switch on the front of the system c Place the teflon tube inside the rotary pump d Insert the front end of the teflon tube inside the dispensing ...

Page 2: ...nning mode 3 Dispense Button Press this button to activate the dispensing process 4 Fast Switch Switch left to rotate Rotary Pump counter clockwise continuously right side will rotate clockwise 5 Rotate Speed Button Set the Rotary Pump rotating speed 0 50 6 Rotate Speed Display Display currently rotary speed 7 Counter Clockwise Button Press down to active the Rotary Pump rotating counter clockwise...

Page 3: ... make sure the Rotary Pump rotating speed and direciton is correct f Turn off the training mode then the adhesive will dispense and reverse according the the timer setting g Use Fast Switch to unload the adhesive inside the Teflon Tube back to the adhesive bottle to save usage 5 Three main reasons that control the dispensing volume Needle type and size Teflon Tube Size Rotary Pump Speed 6 Maintena...

Page 4: ...e vacuum setting and de bubble the adhesive before filling replace with different type of needle replace needle replace Teflon Tube 8 Limited warranty Ever Sharp warrants this product to the original purchaser for a period of one year from date of purchase to be free from material and workmanship defects but not normal wear and tear abuse and faulty installation Defective product or subassembly an...

Reviews: