background image

DUO II / DUO II Pro series UPS – Instruction Manual  

2010/03/19

 

www.ever.eu

 

CONNECTING THE UPS 

Due to the type and placement of cut-outs present in the UPS the safety circuits of 

the building function as one of the protection measures. This is essential to provide 

the UPS with shorting protection. The UPS may only be connected to a ~230V 

mains socket equipped with a grounding bolt.

 

WARNING! After unpacking, place the device in the chosen spot without connecting 

the load (computer, monitor etc.), connect it to the mains and turn on the UPS with 

the switch located on the front panel in order to charge the internal batteries. After at 

least 10 h (see Table 1) the batteries will have charged and the user may continue 

with the installation procedure.  

Batteries’ batteries reach their full capacity after approximately a month of 

mains operation mode.

 

Next, connect the computer or other peripherals to one of the sockets located on the 

rear  panel  of  the  UPS.  You  can  connect  a  total  of  four  devices  whose  total  power 

does  exceed  80%  of  the  UPSs  maximum  power.  Remove  the  plug  from  the  mains 

socket and verify the operation of the system. 

After  installing  the  software  on  the  computer  you  should  also  verify  the 

communication (PRO models). 

DESCRIPTION OF THE UPS’S OPERATION 

It is possible to start the UPS in the battery operation mode without connection to the 

mains  (the  connected  devices  are  powered  until  input  voltage  returns  or  until  the 

batteries are depleted).  

The  UPS  will  indicate readiness by  lighting  up  the  LEDs and a  continuous  acoustic 

signal  and  then  switch  on  in  the  battery  operation  mode,  powering  the  devices 

connected to the output.

 

WARNING! Since computer monitors draw varied current upon switching on, it 

may lead to problems with starting the UPS and the connected devices. In such 

cases please try to start the UPS again when the mains voltage is back. 

The main task of the UPS is to supply power to the devices connected to its output. 

Power is supplied from the batterry in cases when the level of input voltage exceeds 

the  upper  or  lower  threshold  or  when  lack  thereof  is  detected.  The  support  time 

Summary of Contents for Duo II 1000

Page 1: ......

Page 2: ...FEGUARDS 9 Against overloads 9 Against shorting 9 Against overloads 9 COMMUNICATION BETWEEN THE UPS AND A COMPUTER 10 SOFTWARE INSTALLATION 10 INSTALLATION AND CONFIGURATION OF THE POWERSOFTPERSONAL SOFTWARE 10 Installation on computers with Windows 10 Installation on computers with Linux Unix 11 Software updates 12 ADDITIONAL REMARKS 13 CUT OUT 13 UPS AND POWER GENERATORS 13 USING THE TELECOMMUNI...

Page 3: ...n purpose of the EVER DUO II DUO II Pro series UPSs is to protect computers computer peripherals and fiscal devices GENERAL FEATURES OF THE UPS Four IEC 320 outlet sockets with emergency power supply Synchronisation with the mains Cold start option of starting the UPS without connection to the mains Acoustic signalling of low battery level Microchip control of all operating parameters Resistance t...

Page 4: ...19 www ever eu 4 ELEMENTS OF THE UPS FRONT PANEL 1 Power switch 2 Operation mode indicator 3 Malfunction indicator REAR PANEL 1 4 x IEC 320 outlet sockets 2 10 A circuit breaker 3 Power lead 4 RJ telephone filter 5 Communication port USB only DUO II Pro UPSs ...

Page 5: ...ree lead sockets two poles and earthing connecting the device to any other socket may result in electric shock A device powered via a lead with a plug has an earthing lead that carries away the leakage current from the receivers e g computer equipment the total leakage current must not exceed 3 5 mA Users are forbidden to carry out any maintenance activities as they may lead to injury or death Any...

Page 6: ...NG The device is delivered with its accumulator connected Check the contents of the packaging The packaging should contain The UPS quick reference guide IEC 320 cables 2 sets USB cable only PRO models warranty card CHOOSING THE INSTALLATION SPOT The battery should only be used in rooms whose dustiness temperature and moisture levels conform with the device s specification see Technical parameters ...

Page 7: ...can connect a total of four devices whose total power does exceed 80 of the UPSs maximum power Remove the plug from the mains socket and verify the operation of the system After installing the software on the computer you should also verify the communication PRO models DESCRIPTION OF THE UPS S OPERATION It is possible to start the UPS in the battery operation mode without connection to the mains t...

Page 8: ... stage of depletion of the battery while in the battery operation mode is signalled optically and acoustically see Table 1 Switching on the power switch is accompanied by a continuous acoustic signal and lighting of the green and red LEDs Next the UPS switches to the appropriate operation mode Table 1 Mains operation mode Green LED is constantly lit Battery operation mode Green LED blinks every 4 ...

Page 9: ...rovided by a circuit breaker Additionally the output of the UPS in battery operation mode is protected by an electronic safeguard whose triggering is indicated by constant light of the red LED and a continuous acoustic signal If the shorting at the UPSs output persists for longer that 0 5 seconds while in battery operation mode voltage is disconnected from outlet sockets while the UPS remains in t...

Page 10: ... beginning the installation of PowerSoft Uninstall the current version of PowerSoft or any other control software in situations where the user is changing the UPS protecting the computer If the UPS will communicate with the PC via a USB cable this cable should be initially disconnected from the computer The software installer will prompt the user to connect the communication cable at the appropria...

Page 11: ...enu You can also uninstall PowerSoft from the Add and remove programs menu in the control panel Installation on computers with Linux Unix The binary version of the application for Linux Unix systems is provided in the following formats CentOS RedHat Suse Linux Fedora Core For the CentOS RedHat Suse Linux and Fedora Core systems the software is provided in the form of a RPM package The software can...

Page 12: ...er for Windows systems has a built in automatic updater PowerSoft may regularly check for new software versions and notify the user when updates are available By default the software check for updates after user log in This setting may be changed in the Update configuration item in the system s programme menu Linux Unix systems In the case of Linux Unix systems PowerSoft may be updated by download...

Page 13: ...voltage which depends on the changes in the load values If the variations of frequency of the output voltage exceed the allowed tolerance thresholds ie 5Hz the UPS will consider the parameters of the input voltage to be incorrect and it will switch to battery operation mode USING THE TELECOMMUNICATION FILTER In order to protect the analogue telephone line and connected telecommunication devices su...

Page 14: ... Sp z o o shall not be responsible for any mechanical damages that occur in transport DISPOSAL Appropriate utilisation of used up electric and electronic equipment helps to avoid consequences resulting from the presence of dangerous materials as well as inappropriate disposal and processing of such equipment which may be hazardous to human life and the environment Act dated 29 July 2005 on used up...

Page 15: ...holds Mains UPS 190 259 V 5 Shape of output voltage Same as input Filtering of output voltage LC Time to switch to battery operation mode 6ms BATTERY OPERATION MODE Output voltage effective value 230 V 10 Shape of output voltage Modulated sinus Switching thresholds UPS mains 200 249 V 5 Frequency of output voltage 50 Hz 1Hz Shorting safeguard Electronic Overload protection Electronic Batterry 1 x ...

Page 16: ...out the term specified in the warranty document The company s liability under the warranty is limited to repairs or replacement of products with such defects The manufacturer shall make the decision as to how the defect is removed The warranty does not cover devices with mechanical damages that occurred as a result of negligence of incorrect use nor devices subjected to any modifications made by t...

Reviews: