Notice
Why did it occur?
What should I do?
i
USB connection
The "USB connection" notice will appear when
the pump is connected to a PC and the data are
being exported.
Wait until the data are ready to be exported.
i
Delivery is zero
The "Delivery is zero" notice will appear when
the delivery settings for the basal rate and bolus
settings are both set to zero.
Press
to acknowledge the notice and enter
the complete delivery settings (medical professio‑
nals only).
Section
6
provides corresponding
instructions.
i
Bolus amount is zero
The "Bolus amount is zero" notice will appear
when the set bolus dose is zero.
Press
to acknowledge the notice and enter
the delivery setting (medical professionals only).
Section
6
provides corresponding
instructions.
i
Bolus not ready
The "Bolus not ready" notice will appear when
the bolus is triggered while the basal rate is being
administered.
Press
to acknowledge the notice and repeat
the bolus delivery at a time when the basal rate is
not being administered (motor is not turning).
Section
4.2
provides corresponding
instructions.
i
Reset
The "Reset" notice will appear when the pump
parameters are reset to the factory default
settings.
Then reenter the settings. To be performed by
medical professionals only.
Section
6
provides
corresponding instructions.
Notice
Why did it occur?
What should I do?
i
Pump not ready
You have attempted to start the pump before
executing the "Prepare the infusion set" function.
Press
to acknowledge the notice and prepare
the infusion set in accordance with the instructions
in
S
ection
4.3
.
i
Battery too low for
filling
The "Battery too low for filling" notice will appear
when the rechargeable battery is not adequately
charged to complete the filling process.
Press
to acknowledge the notice and place
the pump in the docking station for filling in ac‑
cordance with the instructions in
S
ection
3.1
.
i
Bolus lockout
active
You have attempted to deliver another bolus while
bolus lockout time is enabled.
Press
to acknowledge the notice and wait
until the lockout time has elapsed. You can then
deliver another bolus.
i
Reservoir empty
The "Reservoir empty" notice will appear when
the amount of drug remaining in the reservoir is
less than the set bolus dose.
Press
to acknowledge the notice and change
the infusion set and reservoir in accordance with
the instructions in
S
ection
4.4
.
i
No reservoir
The "No reservoir" notice will appear when you
attempt to execute the "Prepare the infusion set"
function, but no reservoir has been inserted.
Press
to acknowledge the notice and insert a
new reservoir in accordance with the instructions
in
Section
3.1
.