Setting of the throttle valves :
Position the grab for rotation, and rotate it.
Set the rotation speed by adjusting the flow control valve in the carrier
‟s rotation pipe.
The proper rotation speed is 7~12 rpm and it must not exceed 15 rpm.
IMPORTANT!
It will cause personal injury, damage to the grab, or inconvenience operation if the rotation
speed of the grab is too high. The service life of the rotation bearing will reduce if it exceeds
15 rpm.