Document No. 1112M001 Revision 1.8 Date: June 2013
15
Avoid damage to any paint finishes by protecting with suitable
sundry material (HD foam, carpet tiles, cloth rags etc).
Make all power cables ends safe by insulation before installing
the generator.
►
Support the lowered tower at a suitable height to receive the
generator. Be sure that the support can bear the total weight
after the generator is mounted. Allow for 250kg (550lbs).
►
Support the generator at a similar height with the mounting
flange in line with the tower flange. Allow for 250kg (550lbs)
Observe polarity on electrical connections.
Cve (red) and –ve (black) generator
output cables correctly. Reverse polarity will
damage the generator and any connected
equipment.
►
Remove the short across the generator
wires. Make and complete the electrical
connection between the generator and the tower cable. The
250Vdc generator can output up to 550Vdc when unloaded.
The 48Vdc generator can deliver up to 80A.Use properly rated
connectors and ensure that this connection is good and secure and
completely watertight. The generator earth wire
is connected and extended down to the
ground earth for the tower.
►
Fit the generator to the tower while storing the
cable and connector down the inside of the
tower. Fit the resilient kit in the order as
shown above. Ensure that no cable is
damaged during this operation
►
. Torque the flange bolts to
120Nm (88ft lbs)
.