Document No. 1112M001 Revision 1.8 Date: June 2013
2
Warranty Registration (Failure to return may render the warranty to be void)
Please complete and return this page within three months after the product delivery date or
within one month following the commissioning date. Attach a picture of your installation
Name of Product: _________________________________
Product Serial Number _________________________________
Pitch Control Serial Number _____________________________
Blade Serial No. (1)_______________ (2)_______________ (3)_____________
Delivery Date____________or Commissioning Date___________
Name and Address of Owner
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Telephone: ______________________________________________________________
Email: ______________________________________________________________
Installation / Site Address (GPS co-ordinates are appreciated)
________________________________________________________________________
________________________________________________________________________
Commissioning Check List
Section
Operation / Procedure
Verified
4.2
All tail assembly M6 fasteners torqued to 10Nm (7.5ft lb)
4.3
Tail boom weld assembly 2 x M12 to 50Nm (36ft lb)
4.3
Tail boom weld assembly 8 x M10 to 50Nm (36ft lb)
4.4
Generator electrical connection secure and insulated
4.4
Generator fitted to the tower 8 x M16 to 120Nm (88ft lb)
4.5
Tail assembly to the boom 2 x M10 to 35Nm (25ft lb)
4.6
Blades properly installed (serial number forward)
4.6
Blade bolts 6 x stainless M16 torqued to 90Nm (65ft lb)
4.8
Nacelle 2 x M6 nuts + 4 x M5 screws stainless to 3Nm (3ft lb)
4.8
Nosecone to stiffener ring 6 x M6 stainless to 4Nm (3ft lb)
4.8
Nosecone to posts 3 x M8 stainless to 10Nm (7.5ft lb)
GENERAL COMMENTS:
………………………………………………………………………………………………………………
………………………………………………………………………………………………………………
Send to: Kestrel Wind Turbines, P.O. Box 3191, North End, Port Elizabeth, 6056, Eastern
Cape, South Africa Or email to:
kestrel.admin@eveready.co.za
OR Fax: +27 41 394 8183
Type of Tower
Installation Engineer
Comissioned Date