10
Troubleshooting Guide
The compressor or entire system fails to start.
The ON/OFF switch may be set to OFF.
Turn on and wait for the motors to show signs
of operation.
The power cord may not be connected. Check
for proper connection. In cases of damage to the
power cord or plug, immediately mark the unit as
out of order until the damaged part is replaced.
The outlet may not be sending power or the
power supply breaker may be switched off. Unplug
the unit and contact a licensed electrician for
inspection and/or repairs.
The compressor operates continuously
or for prolonged periods.
The condenser coil or condenser coil air filter may
be clogged with dust, grime or debris. Clean them
following the instructions on page (9).
The sliding doors may not be sealing properly.
Check for any blockage in the door tracks or for
improper product placement that may prevent
the doors from fully closing.
The room’s ambient temperature may be higher
than 86°F (30°C). Provide ample ventilation or
additional cooling to the room or relocate the unit
to a larger space with lower ambient temperature.
Troubleshooting Guide
The unit may be installed in close proximity to
heat sources such as ovens, stoves, heaters or
direct sunlight. Relocate the unit away from these
sources.
The unit may be installed without clearance or
proper ventilation. This forces the compressor to
operate constantly in order to maintain cabinet
temperature. Provide additional exhaust vents and
observe the clearance allowance specified on
page (3).
The cabinet temperature is too warm.
The condenser coil air filter may be clogged
with dust, grime or debris. Clean it following
instructions on page (9).
The sliding doors may not be sealing properly.
Check for any blockage in the door tracks or for
improper product placement that may prevent
the doors from fully closing.
Hot food items may have been placed in the
cabinet. Store only room temperature food items.
The room’s ambient temperature may be higher
than 86°F (30°C). Provide ample ventilation or
additional cooling to the room. Relocate the unit
from extremely small spaces without ventilation.
The unit may be installed in close proximity to
heat sources such as ovens, stoves, heaters or
direct sunlight. Relocate the unit away from these
sources.
In most cases, your Everest product may be exhibiting behavior that is typical
of standard operation. Observe the following when troubleshooting symptoms.