background image

3

Installation Instructions

Installation Instructions

1.   Inspect for any freight damage upon delivery 

of the unit. If damage is detected, immediately 
report it to an Everest representative. Everest 
is not responsible for damage that occurs 
during shipment.

2.   Keep the unit upright at all times. The 

compressor contains oil, refrigerant, 
lubricants, and various chemicals. When tilted, 
these fluids may shift and travel to sections 
where they don’t naturally occur. This will 
lead to system contamination and compressor 
failure.

3.   Select a location with good air ventilation. 

Poor ventilation rapidly increases ambient 
temperature. High ambient temperatures 
exceeding 86°F (30°C) promote excessive 
compressor activity in order to maintain the 
desired cabinet temperature. This will result in 
decreased performance, advanced component 
failure, and the risk of fire.

4.   Select a location away from heat-generating 

equipment such as stoves, ovens, etc. Heat 
sources rapidly increase the temperature of 
the immediate vicinity. High temperatures 
exceeding 86°F (30°C) promote excessive 
compressor activity in order to maintain the 
desired cabinet temperature. This will result in 
decreased performance, advanced component 
failure, and the risk of fire.

5.   A distance of 6” is required for left side or right 

side clearance wherever a unit’s condenser 
coil is located. This ensures proper ventilation 
and prevents overheating which can lead to 
advanced component failure or the risk of fire.

6.   Select a location with a hard, leveled surface. 

Use a leveling tool on the unit to ensure 
proper alignment. Proper door function 
and condensate removal is dependent 
on accurate balance.

7.   Select a location close to an electrical wall 

outlet to ensure direct connection without 
the use of extension cords.

8.   Select a location away from severe moisture 

conditions. This may compromise the unit’s 
electrical components and lead to electrical 
shocks or the risk of fire.

9.   Select a location that will not expose the unit 

to extremely dusty conditions. Environments 
with high dust and debris content will 
significantly hasten condenser coil and 
condenser coil air filter blockage and will 
result in decreased performance, advanced 
component failure, and the risk of fire.

10.  Do not build an enclosure or cabinet around 

the unit. This will restrict air ventilation 
resulting in elevated compressor activity, 
decreased performance, advanced component 
failure, and the risk of fire.

11.  The unit is not intended for use in food trucks. 

Limited space, lack of ventilation, and ambient 
temperatures exceeding 86°F (30°C) typical to 
this setting will result in elevated compressor 
activity, decreased performance, advanced 
component failure, and the risk of fire.

12.  The unit is intended for indoor use only. 

Outdoor use will cause a decrease in 
performance, advanced component failure, 
and the risk of fire.

13.  The unit comes with an interior drain hole 

plug. Keep this plugged in during normal 
operation and unplug when cleaning the 
interior to allow water to drain.

14.  Install drain hoses to the back of the unit 

when cleaning the interior.

This section applies to all Everest products. Correct installation ensures proper performance 
and longevity of your appliance. Professional installation by a trained refrigeration technician 
and electrician is recommended. Warranty is void if the following guidelines are not met.

Summary of Contents for ESC47L

Page 1: ...Owner s Manual ESC47L ESC47R ESC59L ESC59R ESC71L ESC71R ESC83L ESC83R www everestref com Countertop Refrigerated Display Cases ...

Page 2: ...this page intentionally left blank ...

Page 3: ...9L ESC59R ESC71L ESC71R ESC83L ESC83R Everest Owner s Manual Contents Hydrocarbon Guidelines 1 2 Installation Instructions 3 4 General Safety 5 Electrical Safety 6 Operation 7 Care and Maintenance 8 9 Troubleshooting Guide 10 11 Warranty Information 12 13 14 ...

Page 4: ...wed CAUTION Risk of fire or explosion Flammable refrigerant used Dispose of properly in accordance with federal or local regulations CAUTION Risk of fire or explosion due to puncture of refrigerant tubing follow handling instructions carefully Flammable refrigerant used WARNING THIS UNIT USES R290 A HYDROCARBON PROPANE REFRIGERANT THAT IS ENVIRONMENTALLY FRIENDLY BUT IS ALSO HIGHLY FLAMMABLE AND E...

Page 5: ...s or high surface temperatures Avoid unit installation in small confined spaces Ensure ample ventilation at all times Keep all exhaust vents free of any blockage or obstruction Do not rely on smell to detect potential leaks of propane refrigerant Propane refrigerant is a high purity propane gas and does not contain odorants or stenching agents These additives are typically used in fuel grade propa...

Page 6: ...door function and condensate removal is dependent on accurate balance 7 Select a location close to an electrical wall outlet to ensure direct connection without the use of extension cords 8 Select a location away from severe moisture conditions This may compromise the unit s electrical components and lead to electrical shocks or the risk of fire 9 Select a location that will not expose the unit to...

Page 7: ...ication Bottom Level Countertop Refrigerated Display Cases come with adjustable food trays which offer medium to low temperature coverage The trays are made of durable food grade plastic 1 Place the tray top side up for medium temperature application 2 Place the tray top side down for low temperature application ...

Page 8: ...plosion Objects may also fall when opening and closing doors which may lead to serious injury Do not place any weight on top of the unit nor use it as a stand This can damage the unit s structural integrity If you suspect a refrigerant leak or a compromised refrigeration system disconnect the unit and contact Everest Refrigeration immediately When disposing the unit remove all doors and trays to a...

Page 9: ...ng of circuit wires which may lead to a fire Do not use extension cords adapter plugs or other third party electrical connections Everest is not responsible for issues resulting from improper electrical connections electrical power failures and voltage fluctuations Everest does not recommend the use of generators in conjunction with the unit due to voltage fluctuations that may compromise electric...

Page 10: ...ior This lets the temperature fully stabilize Use this time to verify proper installation and operation The default temperature setting of 38 F is not adjustable To display food items at medium temperature application mount the food trays top side up To display food items at low temperature application mount the food trays top side down Manual Defrost The Countertop Refrigerated Display Case is no...

Page 11: ... blockage in the tracks Clean the interior of the unit with mild soap and warm water Remove the interior drain hole plug to allow water to drain out Ensure that the exterior drain hoses are connected to the rear of the unit Wipe interior until dry Clean the exterior of the product with mild soap and water Do not use steel wool strong acids concentrated detergents bleaches cleaning waxes polishers ...

Page 12: ...before performing maintenance 1 2 3 4 5 2 Locate the condenser coil grill at the rear of the unit Push down on the lock tabs on the grill to access the condenser coil air filter The filter is a black rectangular leather framed mesh suspended over the condenser coil 3 Push up the condenser coil air filter to detach from the frame 4 Wash the condenser coil air filter with lukewarm water and dish soa...

Page 13: ...ide The unit may be installed in close proximity to heat sources such as ovens stoves heaters or direct sunlight Relocate the unit away from these sources The unit may be installed without clearance or proper ventilation This forces the compressor to operate constantly in order to maintain cabinet temperature Provide additional exhaust vents and observe the clearance allowance specified on page 3 ...

Page 14: ...tine maintenance Mild condensation in warmer ambient temperature conditions may occur due to frequent or prolonged door operation Condensation on the unit s exterior surfaces Highly humid environments will contribute to the condensation build up on exterior panels Providing ample ventilation and air movement to a space will reduce the humidity level The sliding doors may not be sealing properly Ch...

Page 15: ...anently affixed label that contains the model serial barcode numbers and refrigeration data of your Everest product This tag is located in the upper left or right interior compartment for models with doors or the exterior left or right exterior housing for models with drawers Please retain this information for service related purposes 8 Warranty Information Register your Everest product within thi...

Page 16: ...limitations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty A NON WARRANTY PARTS EVEREST excludes specific parts exposed to normal wear and tear These parts include but are not limited to lamps gaskets casters shelves and shelf clips pans bin and pan dividers and airflow guards B INDIRECT OR CONSEQUENTIAL DAMAG...

Page 17: ...A Step Above The Standard 201 W Artesia Blvd Compton CA 90220 Tel 800 444 6285 310 323 6586 Fax 310 323 7524 310 761 1127 www EVERESTref com v0892019 ...

Reviews: