4
Installation Guide
Installation Guide
Install the unit on a hard and level surface
or the unit could produce undesired noises.
The unit should be positioned at least 7”
away from the wall for proper ventiliation.
Indoor Use Only
Outdoor use may cause a decrease in
performance and significant damage
to the unit.
Dusty and High Humidity Areas
Dusty environments will cause the
condenser coil to prematurely clog which
will require it to be cleaned more often.
High humid
environments
could cause the
unit to rust.
Do not build an enclosure or cabinet
around the unit.
Restricting the airflow around the unit’s
condenser area will cause the compressor to
work harder, which can result in compressor
failure and the unit not
being able to maintain
the desired temperature.
Select a location away from other heat
and moisture generating equipment
such as stoves, ovens, dish washers, etc.
High ambient temperatures cause the
compressor to work harder, which can result
in compressor failure and the
unit not being in compre-
ssor failure and the unit not
being able to maintain the
desired temperature.
REFRIGERATION
7”
Back Wall
7”
Keep the unit upright at all times during
delivery. Tilting the unit during delivery
will cause harm to the refrigeration system.