EAN7360 / EHN7360 / EZN7360
10
EHN7360
The I/O terminal block, located on the camera module, can be used to develop applications for alarm
input and output, two-way audio, TV-output or a variety of other functions.
Note:
1.
You can unplug the terminal block from the camera module for easier wiring.
2.
Microphones and speakers with a (built-in) amplifier and external power supply are required.
3 2 1
6 5 4
9 8 7
12 11 10
16 15 14 13
Camera Module
Pin Assignment
No. Functions
No.
Functions
1
12 VDC Input
9
Audio Output (Line-out)
2
Digital GND
10
Audio GND
3
Alarm Out
Alarm Output (+)
11
CVBS Output
4
Alarm COM (-)
12
Digital GND
5
Alarm In
Alarm Input (+)
13
AC24V+
6
Digital GND (-)
14
AC24V-
7
Audio Input (Line-in)
15
RS485_A
8
Audio GND
16
RS485_B