EBH5102 1080p Mini IR Ball Camera
11
selecting an area block, enter the BLC POS / SIZ and X / Y setup page, a “POSITION” sign
displayed on the screen. Use the direction buttons to move the area to the desired position.
Press the
Enter / Confirm
button to confirm the position, a “SIZE” sign displayed on the screen.
Use the direction buttons to adjust the size for the area.
4.1.7 System
Press the
Enter / Confirm
button to enter the submenu.
F / W VER
1.00
PAL
DEFECT DET
Press to select the DPC (Defective Pixel Correction) level of defect detector. Please notice; do
not use this function without cover the lens. The camera will automatically correct pixel
defects. Misoperation will cause the abnormal image.
CAM TITLE
Switch to On and then enter the submenu to set up a camera name displayed on the screen.
RS-485
Use the
and
buttons to select ID, BAUDRATE, PROTOCOL and ID DISPLAY. The default of
protocol is EVF-1 (EverFocus).
DOUT SCALE: Digital Output Scale
Use the
and
buttons to select FULL or COMP. This function is used to select the value
range of auto brightness control. The value range of FULL and COMP is as below:
FULL:
0-255
COMP:
16-255