background image

 

Precautions 

1.

 

Do not install the camera near electric or magnetic fields.

 Install the camera away from 

TV/radio transmitters, magnets, electric motors, transformers and audio speakers since the 

electromagnetic fields generated from these devices may distort the video image or 

otherwise interfere with camera operation. 

2.

 

Never disassemble the camera beyond the recommendations in this manual nor introduce 

materials other than those recommended herein. 

Improper disassembly or introduction of 

corrosive materials may result in equipment failure or other damage. 

3.

 

Try to avoid facing the camera toward the sun

. In some circumstances, direct sunlight may 

cause permanent damage to the sensor and/or internal circuits, as well as creating 

unbalanced illumination beyond the capability of the camera to compensate. 

4.

 

Keep the power cable away from water and other liquids and never touch the power cord 

with wet hands. 

Touching a wet power cord with your hands or touching the power cord 

with wet hands may result in electric shock.

 

5.

 

Never install the camera in areas exposed to oil, gas or solvents. 

Oil, gas or solvents may 

result in equipment failure, electric shock or, in extreme cases, fire.

 

6.

 

Cleaning. 

For cameras with interchangeable lenses, do not touch the surface of the sensor 

directly with the hands. Use lens tissue or a cotton tipped applicator and ethanol to clean 

the sensor and the camera lens. Use a damp soft cloth to remove any dirt from the camera 

body. Please do not use complex solvents, corrosive or abrasive agents for cleaning of any 

part of the camera. 

7.

 

Do not operate the camera beyond the specified temperature, humidity or power source 

ratings.

 This camera is suitable for indoor operation only. Use the camera at temperatures 

within -10°C~50°C (14°F~122°F) and humidity between 20%~ 80%; this device is not rated as 

submersible. The input power source is 12VDC or 24VAC. Be sure to connect the  / - 

polarity and voltage, as incorrect polarity or too high a voltage will likely cause the camera 

to fail, and such damage is not covered by the warranty. 

8.

 

Mounting.

 Use care in selecting a solid mounting surface which will support the weight of 

the camera plus any wind, snow, ice or other loading, and securely attach the camera to the 

mounting surface using screws and anchors which will properly support the camera. If 

necessary (e.g. when mounting to drop ceilings) use a safety wire to provide additional 

support for the camera. 

 

 

Summary of Contents for ED910

Page 1: ...ED910 ED930 720p Analog High Definition True Day Night Indoor Dome Camera User s Manual Copyright EverFocus Electronics Corp Release Date Nov 2014...

Page 2: ...y result in equipment failure electric shock or in extreme cases fire 6 Cleaning For cameras with interchangeable lenses do not touch the surface of the sensor directly with the hands Use lens tissue...

Page 3: ...evision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiv...

Page 4: ...4 Contents 1 Introduction 5 1 1 Packing List 5 1 2 Features 6 2 Cable Description 6 3 Installation 7 3 1 Installation and Adjustment 7 4 Configuration in the OSD Menu 13 5 Specifications 17...

Page 5: ...des true day night enhanced images in low light environments with guaranteed ZERO ghosting The cameras are equipped with 3 axis rotation design allowing wall or ceiling mounting Your choice of vari fo...

Page 6: ...subjects vivid and high SN ratio images even under low light environments Support 720p 960H analog signal output which can be easily switched by OSD Easy lock installation by screwing the base plate t...

Page 7: ...ED910 930 eZ HD Indoor Dome Camera 7 3 Installation 3 1 Installation and Adjustment ED910 without LED ED930 with LED Camera Breakdown...

Page 8: ...ion procedure Base Plate Camera Body The Base Plate is unlocked to the Camera Body 1 Stick the Template Plate on the position where you want to attach the camera drill the three holes on the Template...

Page 9: ...o remove the liner Remark Hold the liner with one hand press and pull to remove the liner refer to the arrow label which marked to the liner 4 Push the inner click outward and rotate the base plate co...

Page 10: ...u want to wire the cables through the wall ceiling break the middle part of the base plate 6 Lock the camera body back to the base plate align the arrow marks and rotate the camera body clockwise A cl...

Page 11: ...AHD DVR or a monitor 8 Optionally connect the camera to a monitor using the supplied Test Lead for adjusting camera angles focus zoom and configuring OSD menu a Connect one end of the Test Lead to th...

Page 12: ...below Press the DOWN button key over 5s to switch video format from PAL to NTSC Press the LEFT button key over 5s to switch video output from 720p to 960H 720p is the default Press the RIGHT button k...

Page 13: ...1 50 FLK 1 200 1 400 1 1000 1 2000 1 5000 1 10000 1 50000 Iris Speed 0 15 0 Manual 2 Exposure Shutter NTSC 1 30 1 60 FLK 1 240 1 480 1 1000 1 2000 1 5000 1 10000 1 50000 X2 X4 X6 X8 X10 X15 X20 X25 X3...

Page 14: ...0 100 50 AWB 5 Day Night Ext Ext for ED930 D N Delay 0 60 1 N D Delay 0 60 1 Auto Auto for ED910 D N AGC 1 255 240 D N Delay 0 60 1 N D AGC 1 255 50 N D Delay 0 60 5 Color B W Burst Off On IR Smart Of...

Page 15: ...Off Alarm Sig High Low Time 1 15 3 Default Privacy Off On Select Area1 Area2 Area3 Area4 Display Off Color Position Size Mosaic Position Size Inv Position Size Color White Black Red Blue CYAN Yellow...

Page 16: ...255 1 ID Display Off On Baud Rate 2400 4800 9600 19200 38400 8 Adjust Sharpness Off Auto Level 0 10 6 Start AGC 0 255 50 End AGC 0 255 200 CRT LCD CRT Black Level 0 60 0 Blue Gain 0 100 50 Red Gain 0...

Page 17: ...te Balance ATW AWC SET INDOOR OUTDOOR MANUAL AWB Sync Mode Internal Day Night Ext Auto Color B W True D N with ICR Auto IR LED N A 18 Units IR Distance N A Up to 30m 100ft range depending on scene IR...

Page 18: ...625 8189 www everfocus co jp info everfocus co jp EverFocus China Shanghai Room 403 Ruijin Business Center No 96 Zhaojiabang Road Luwan district Shanghai 200020 China TEL 86 21 6471 2229 6471 2291 FAX...