background image

 

 

 

Safety Notice

 

Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation.    This equipment generates uses and 
can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 

 

However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the interference by one of the 
following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver

 

is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 

FCC Caution:

 Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment. 
 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation. 

 

 

 

 
 

 

Summary of Contents for ED910

Page 1: ...ED910 ED930 720p Analog High Definition True Day Night Indoor Dome Camera User s Manual Copyright EverFocus Electronics Corp Release Date Nov 2014...

Page 2: ...y result in equipment failure electric shock or in extreme cases fire 6 Cleaning For cameras with interchangeable lenses do not touch the surface of the sensor directly with the hands Use lens tissue...

Page 3: ...evision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiv...

Page 4: ...4 Contents 1 Introduction 5 1 1 Packing List 5 1 2 Features 6 2 Cable Description 6 3 Installation 7 3 1 Installation and Adjustment 7 4 Configuration in the OSD Menu 13 5 Specifications 17...

Page 5: ...des true day night enhanced images in low light environments with guaranteed ZERO ghosting The cameras are equipped with 3 axis rotation design allowing wall or ceiling mounting Your choice of vari fo...

Page 6: ...subjects vivid and high SN ratio images even under low light environments Support 720p 960H analog signal output which can be easily switched by OSD Easy lock installation by screwing the base plate t...

Page 7: ...ED910 930 eZ HD Indoor Dome Camera 7 3 Installation 3 1 Installation and Adjustment ED910 without LED ED930 with LED Camera Breakdown...

Page 8: ...ion procedure Base Plate Camera Body The Base Plate is unlocked to the Camera Body 1 Stick the Template Plate on the position where you want to attach the camera drill the three holes on the Template...

Page 9: ...o remove the liner Remark Hold the liner with one hand press and pull to remove the liner refer to the arrow label which marked to the liner 4 Push the inner click outward and rotate the base plate co...

Page 10: ...u want to wire the cables through the wall ceiling break the middle part of the base plate 6 Lock the camera body back to the base plate align the arrow marks and rotate the camera body clockwise A cl...

Page 11: ...AHD DVR or a monitor 8 Optionally connect the camera to a monitor using the supplied Test Lead for adjusting camera angles focus zoom and configuring OSD menu a Connect one end of the Test Lead to th...

Page 12: ...below Press the DOWN button key over 5s to switch video format from PAL to NTSC Press the LEFT button key over 5s to switch video output from 720p to 960H 720p is the default Press the RIGHT button k...

Page 13: ...1 50 FLK 1 200 1 400 1 1000 1 2000 1 5000 1 10000 1 50000 Iris Speed 0 15 0 Manual 2 Exposure Shutter NTSC 1 30 1 60 FLK 1 240 1 480 1 1000 1 2000 1 5000 1 10000 1 50000 X2 X4 X6 X8 X10 X15 X20 X25 X3...

Page 14: ...0 100 50 AWB 5 Day Night Ext Ext for ED930 D N Delay 0 60 1 N D Delay 0 60 1 Auto Auto for ED910 D N AGC 1 255 240 D N Delay 0 60 1 N D AGC 1 255 50 N D Delay 0 60 5 Color B W Burst Off On IR Smart Of...

Page 15: ...Off Alarm Sig High Low Time 1 15 3 Default Privacy Off On Select Area1 Area2 Area3 Area4 Display Off Color Position Size Mosaic Position Size Inv Position Size Color White Black Red Blue CYAN Yellow...

Page 16: ...255 1 ID Display Off On Baud Rate 2400 4800 9600 19200 38400 8 Adjust Sharpness Off Auto Level 0 10 6 Start AGC 0 255 50 End AGC 0 255 200 CRT LCD CRT Black Level 0 60 0 Blue Gain 0 100 50 Red Gain 0...

Page 17: ...te Balance ATW AWC SET INDOOR OUTDOOR MANUAL AWB Sync Mode Internal Day Night Ext Auto Color B W True D N with ICR Auto IR LED N A 18 Units IR Distance N A Up to 30m 100ft range depending on scene IR...

Page 18: ...625 8189 www everfocus co jp info everfocus co jp EverFocus China Shanghai Room 403 Ruijin Business Center No 96 Zhaojiabang Road Luwan district Shanghai 200020 China TEL 86 21 6471 2229 6471 2291 FAX...

Reviews: