(4) ALARM – IN TYPE :
N.O. :
Normal Open
,
N.C. :
Normal Close
(5) ALARM - RESET TYPE:
N.O. :
Normal Open,
N.C. :
Normal Close
(6) ALARM DURATION TIME :
Alarm recording starts from the beginning of alarm and stops at the end of the duration.
The max. duration is NON - STOP, the min. duration is 5 Seconds.
(7) PRE-ALARM OPERATION :
ON :
Record the picture in pre -alarm recording speed in pre -alarm period.
OFF :
No pre -alarm recording before alarm occurs.
(8) RECORDING SPEED :
This is the recording speed in the pre-alarm period.
The max. recording speed is 2/3 (NTSC/PAL) HR.
The min. recording speed is 960 HR.
(9) PRE – ALARM TIME :
The duration of pre -alarm recording period
In 2/3 hour Real Time recording mode, the duration of pre-alarm is about five seconds.
Notice :
If the alarm occurs when it is in standby mode or in normal recording mode,the recording quality will be the
same as the normal recording quality.
If the alarm occurs when it is in timer recording mode , the recording quality will be the same as the value
set in timer recording quality.
MENU
21
Left/Right Button
: Press or to move the cursor to the left or right
Up/Down Button
: Press or to change the value.