Press MENU key and turn the jog dial to select the ALARM
RECORDING SETTING MENU.
The monitor image will automatically record when alarm occurs and stop
s
recording at the end of the alarm
duration period.
Instant recording and timer recording will stop when an alarm occurs.
RECORDING OPERATION:
ON:
Enables alarm recording,
OFF
:Disables alarm recording.
RECORDING SPEED:
Set the recording speed when alarm occurs.
RECORDING QUALITY:
In alarm duration, the recording quality can be set which is different from instant or timer recording.
ALARM – IN TYPE:
Select the type of alarm-in input to be Normal Close (N.C.) or Normal Open (N.O.)
ALARM – RESET TYPE:
Select the type of alarm-reset input to be Normal Close (N.C.) or Normal Open (N.O.)
ALARM DURATION TIME:
Alarm duration from 5 seconds to NON – STOP.
PRE-ALARM OPERATION:
ON:
Enables pre-alarm recording,
OFF:
Disables pre-alarm recording.
RECORDING SPEED:
Set the recoding speed in pre -alarm duration.
Notice:
The recording quality in pre-alarm duration is the same as recording quality before alarm occurs. If the recorder
is not recording before alarm occurs, the recording quality in pre-alarm duration will be the same as instant
recording quality.
Recording
MENU
32
7.2 ALARM RECORDING