background image

 

4. Wire Connection   

 

 

 

 

 

 

 

 

 

 

 

 

Connect the power supply cable (AC24V/DC12V), video output and alarm 

output to the proper connectors shown as Figure 6.   

The V. Phase adjustment screw is located on the termination board.  

The vertical phase may require adjustment to synchronize the vertical 

phase of the camera with other camera in the system when it is to be used 

in the line-lock sync mode.  Make the adjustment when the vertical phase 

of the camera does not match with other cameras.   

 

 

Termination Board 

Video 

Alarm COM 

Micro Switch for Alarm trigger 

GND 

Alarm NO 

Alarm NC 

Power In 

DC12V

 

(+)

 or AC24V

 

V. Phase Adjustment VR 

Figure 6 

Power In   

DC12V

 

(-)

 

or AC24V 

Summary of Contents for EHD150

Page 1: ...1 1 3 3 B B W W R Ru ug gg ge ed d D Do om me e C Ca am me er ra a User s Manual and Operation Instructions EHD150 ...

Page 2: ...o make changes to the product specifications and documentation without notice All the components of the products including accessories components and outlook are based on the agreements of each deals to satisfy all kinds of users Meanwhile please be advised that every step of operation must follow the instruction of this manual to keep EHD150 working under the best condition Please notice that Eve...

Page 3: ...Table of Contents Safety Warning 1 Introduction 2 Specification 3 Installation Instructions 4 Dip Switch Functions 8 ...

Page 4: ...emperature range will stay between 46 to 50 50 to 122 3 Never face the camera toward the sun Never aim the camera at the sun or other extremely bright objects whether it is in use or not 4 Cleaning Do not touch the surface of CCD sensor by hand directly Use a soft cloth to remove the dirt from the camera body Use lens tissue or a cotton tipped applicator and ethanol to clean the CCD sensor and the...

Page 5: ...best choice for vandal resistance Main Features Designed with advanced digital signal processing circuitry for high image quality The high sensitivity of 0 06 lux F 1 6 is achieved by high resolution 1 3 interline transfer CCD DC12V or AC24V switches automatically power supply Line Lock for AC24V S N Ratio reaches 48 dB or more Both board lens and vari focal lens 3 5 8mm or 9 22mm are available Co...

Page 6: ...cal lens only Auto gain control on off switch Back light comp on off switch Line Lock on off switch for 24VAC Gamma correction 0 45 Video output 1 0Vp p 75ohm Power source 12VDC 10 24VAC 10 Power Consumption 5W Max 15W when heater active thermostatically controlled Sync mode Internal Sync Line lock Only AC24V Dimension 130mm x 130mm x 98 9mm Lens Board lens f 3 6 F 2 0 Vari focal F 3 5 8mm F 1 6 H...

Page 7: ...can be easily removed from the bracket 2 Remove the camera To remove the camera first unplug the wire connection on the back of the camera Then loosen the 2 locking screws on the camera base push the camera base to the right toward heater direction as shown in Figure 3 remove the camera from the mounting base Reinstall the camera and the cable while the base mounting is completed Installation Inst...

Page 8: ...ure leaking into the housing apply an appropriate gasket or sealant around the conduit connection Conduit plug setscrew Side conduit entry Back conduit entry Mounting Setscrew Mounting Setscrew Mounting Setscrew Mounting Setscrew The camera comes with a conduit plug pre installed in the PF 1 2 conduit entry on the side The screw can be removed and installed in the back conduit entry Loosen the con...

Page 9: ...ase may require adjustment to synchronize the vertical phase of the camera with other camera in the system when it is to be used in the line lock sync mode Make the adjustment when the vertical phase of the camera does not match with other cameras Termination Board Video Alarm COM Micro Switch for Alarm trigger GND Alarm NO Alarm NC Power In DC12V or AC24V V Phase Adjustment VR 6 Figure 6 Power In...

Page 10: ... is 140 as shown in Figure 7 Adjust the proper camera view angel as needed If a vari focal lens is used you may adjust the focus and zoom of the lens to bring the object in focus Be sure to loosen the locking screws on the lens before you do the adjustments 140 360 7 Figure 7 Lens fixing Screws ...

Page 11: ... between Internal Sync LL off and Line Lock LL on Set the line lock off the camera will synchronize to the internal time base Set the line lock on the camera s vertical synchronization can be driven by the AC signal in the power lines Note Line ...

Page 12: ... picture flicker fiercely turn FL on then the camera will stabilize the speed of electronic shutter at 1 100 NTSC or 1 120 PAL automatically and reduce the flicker immediately The default setting is Normal ES Electronic Shutter Off On ES ON The camera continuously adjusts the shutter speed from 1 60 NTSC 1 50 PAL second to 1 100 000 second according to the luminance conditions of the scene ES OFF ...

Page 13: ...direct drive lens Turn counterclockwise to L to get darker picture Turn clockwise to H to get brighter picture IRIS ALC Adjustment To select light metering method Turn the IRIS ALC Adjustment VR counterclockwise for Average Metering Turn the IRIS ALC Adjustment VR clockwise for Peak Metering 10 ...

Page 14: ...939495 http www everfocus de Hong Kong Office Room 0 10 F Block 3 Camelpaint Building 60 Hoi Yuen Road Kwun Tong Kowloon Hong Kong TEL 852 2758 9871 FAX 852 2758 9056 Japan Office WBG Marive East 18F 1809 2 6 Nakase Mihama ku Chiba city 261 7113 Japan Tel 81 43 212 8188 Fax 81 43 297 0081 P N MD15G00110 EverFocus Electronics Corp Head Office 12F No 79 Sec 1 Shin Tai Wu Road Hsi Chi Taipei Taiwan T...