EMV1200 FHD / EMV800 FHD Hybrid Mobile DVR
137
7.3.1.2 Storage Failure
Log:
Check the box to record alarm events to log data.
Buzzer:
Check the box to enable buzzer when storage fails.
Email Notify:
Check the box to send email notification when storage fails. Email operation
requires valid email entered in the Email setup menu (see
7.3.4.4 Email
).
Network Alarm:
Check the box to send out a network alarm to a client PC when storage fails.
This feature works with EverFocus’ CMS software. You will need to configure the Alarm Server
for the mobile DVR to send network alarms to the client PC (see
7.3.4.7 Alarm Server
).
Send to Xfleet:
Check the box to send the event data to the Xfleet system. Note that for the
Xfleet system to receive event data from the mobile DVR in order to perform the event
actions on Xfleet system, this function must be enabled.
Alarm Output:
Select an alarm output number. When an alarm is triggered, the signal will be
transmitted through the selected alarm output relay.
Output Type:
Output action will be Transparent and cannot be changed (alarm output
remains as long as the alarm condition is active).
Save:
Click to save the settings.