27
Issue: 1.0
- Using the joystick [
▶
] to select Auto (On)/Manual (Off).
- Press [Open] button or use joystick to save settings.
- Press [Close] button or use joystick to return to previous menu {Dome Motion Setup} (Back).
NOTE* In order to call an action (Preset, Pattern, Tour or Scan), you must save Preset, Pattern, Tour, or Scan
first.
3.6.4 Calibration Setup
- Set calibration mode for Manual/Auto using the joystick [
▶
].
- In manual mode, select {Calibration} to execute {Calibration} using the joystick,
and press [Near] button or use joystick to continue.
- Set {Error Message Display} for On/Off using the joystick [
▶
].
- Press [Open] button or use joystick to save settings.
- Press [Close] button or use joystick to return to previous menu (Back).
Note: {Calibration} is a function for correcting an error on the angle of Pan/Tilt automatically.
{Calibration} can be set for Manual/Auto. In Manual mode, if there is an error on the angle of the dome, execute
{Calibration}. Press [Near] button to continue calibration or press [Far] button to cancel calibration.
In Auto mode, when there is an error on the angle of the dome, the dome is corrected automatically. The motor of the
Pan/Tilt will adjust its angle automatically.
{Error Message Display} is a function for displaying an error message to let a user know {Sensing error} on the monitor.