EZN3160/3260
8
6.
Access the camera live view. See
5. Accessing the Camera
. Or connect a handheld test monitor to
the CVBS wire on the Cable Assembly for adjusting viewing angles.
7.
To adjust the camera angles:
Pan Adjustment:
Unscrew the Set Screw using the supplied Thinner Hexagon Wrench. Twist the
Camera Body forcefully until it unscrews from the Camera Base. Rotate the camera by 360° to the
desired position and screw the E-Z Lock Ring until it locks against the Camera Base. Screw back
the Set Screw.
E-Z Lock Ring
Set Screw
360
°
Camera Base
Camera Body
Tilt Adjustment:
Loosen the Tilt Screw using the provided Hexagon Wrench and adjust the tilt
angle by 90°.
Tilt Screw
90
°
Rotational Adjustment:
Loosen the Rotate Screws on both side of the camera body using the
providing Hexagon Wrench and rotate the camera by 360° (180° to the left / 180° to the right).
Rotate Screw
180
°
180
°
8.
To adjust zoom and focus, please use
Lens Control
buttons on the Live View window. Please refer
to
5.4 Live View Window
in the
User’s Manual.
Note:
Before start operating the IP camera, please make sure the camera date and time are
correct. To configure the camera date/time, go to System > Date/Time setting page on Web UI.