PARAGON960 x4 32CH
108
6.7.5
Alarm Server
You can send out the alarm notifications to EverFocus’s CMS software. Please also consult the
CMS’s user manual for network alarm settings.
Figure 6-37
Server IP1~3:
IP address of client PC. The network alarm can be transmitted to up to 3
addresses.
Protocol:
Select the protocol type for alarm transmission. Note the protocol selected here
should match the protocol set up for the CMS alarm server.
UDP: User Datagram Protocol.
TCP: Transmission Control Protocol.
Port:
Select the transmission port for network alarm messages. The port setup here should
match the port set up for the CMS alarm server.
Network ID:
The network ID is an identifier for the alarm transmitter (DVR sending the
alarm).