EHN7221/7260/7360
50
7.1.9.
Serial Communication
This function can only be set up in the
Advanced
tab.
【
RS485 Setting
】
Baud Rate
: This field is to set the speed at which is used to transmit instruction or information
through the RS-485 port on the video encoder. There are six different speeds, 2400 / 4800 / 9600 /
19200 / 38400 / 57600.
Data Bit
: This field is the data bit at which you will be transferring.
Stop Bit
: This field is to set the stop bit for the RS-485 connection. There are two different stop bits,
1
or
2.
Parity
: This field is to select the parity level at which you will be connected. You can choose
between
None
,
Odd
, or
Even
parity levels.
【
Server Setting
】
To set up server for data transmission, enter
IP Address
,
Username
and
Password
and check the
Enable
box. Click
Apply