7.1.3 User setting menu 

To enter the user setting mode, first turn on the 

main power switch and then push and hold both 

the 

ON/OFF 

button  and  the 

SET 

button  for  5 

seconds. The display will show the following; 

1.

Language Setting

 

(Lang)

Use 

+

  or 

  buttons  to  choose  the  desired

language: English, Italian, Spanish, German

and French.

Press  the

  SET

  button  to  confirm  the

selection and move to the next option.

2. Vacuum Mode Setting  (Vac Type)

It  is  possible  to  select  the  percentage  of

vacuum  desired  within  the  chamber  or

length of time. By using the 

or 

 buttons

to make the selection.

0: time in seconds

1: vacuum percentage

Press  the  SET  button  to  confirm  the

selection and move to the next option.

3. Display Setting (Display)

It  is  possible  to  set  the  display  mode

(PRINTER  OPTION).  By  using  the 

+

  or 

buttons to make the selection.

0:  fixed: hour/date

1: intermittent: hour/date

Press the SET button to confirm the

selection and move to the next option.

4. Time/Date Setting

It is possible to set time and date by using

the buttons 

or 

.  Press the 

SET

 button,

to  move  the  cursor  to  the  next  segment.

Time  is  set  in  24h  format  and  date  is

DD/MM/YY  i.e.  07

th

  September  2016

appears as 07/09/16.

Press  the  SET  button  to  confirm  the

selection and move to the next option.

5. User Name Setting

It  is  possible  to  insert  the  user  name  by

following method:

Press 

or 

 buttons to choose

characters, then press SET to move to the

next segment. By pressing the SET button,

it is possible to pass over the empty

positions and then confirm the set

parameters to close this menu. Afterward

the user’s name will appear

.

7.1.4_Program setting

 

Switch  the  machine  on  by  pressing  the  button 

ON/OFF

.  The  following  will  appear  in  the 

screen: 

The number 

1

 indicates which program is being 

used. By pushing the 

or

 

 buttons it is possible 

to change to another program (20 programs). 

1. Vacuum time setting

By pressing the 

SET

 button for 5 seconds in

each program, the following will appear:

By using the 

or

 

 buttons it is possible to 

increase or decrease the seconds (between 

0 and 50) of vacuum.  

By  pressing  the 

SET

  button  it  will  confirm 

the selection and move to the next option.  

2. Vacuum Percentage Setting

(VACUUM MODE OPTION)

By pressing the 

SET

 button for 5 seconds in

each program, the following will appear:

By  using  the 

or

 

  buttons  it  is  possible  to 

increase or decrease the percentage (between 0 

and 99) of vacuum.  

By  pressing  the 

SET

  button  it  will  confirm  the 

selection and move to the next option.  

3. Intermittent Pump Setting

(Liquids and Creams)

SOFT VACUUM OPTION)

This  option  allows  the  pump  to  run

intermittently  when  vacuuming  liquids  and

creamy products.

By pressing the 

or

 

 buttons it is possible to 

set the type of vacuum the pump will deliver. 
When this cycle is selected, the cycle will 

consist of 4 seconds of vacuum and 7 second 

--- Program   1 

Vacuum 

   30 

Vacuum 

 99% 

Vacuum Type  1 

Summary of Contents for PrepRite PVS27-6-1

Page 1: ...Vacuum Sealing Machine Operation and Care and Maintenance Manual For PVS27 6 1 PVS32 8 1 PVS32G 8 1 PVS42 12 1 PVS42G 12 2 PVS42GP 12 1 PVS52 25 1 PVS52 25 2 PVS52G 25 2 This appliance is for commerci...

Page 2: ...rstood by all operators and users 1 This appliance must be installed on a stable and level surface 2 DO NOT install this appliance in any area where it may be affected by any adverse conditions such a...

Page 3: ...ersons unplug from the power supply before servicing This appliance must service by qualified service personnel Failure to properly maintain and service to this appliance can and will cause injury or...

Page 4: ...standards regarding the design construction and intended use of the machine will relieve the manufacturer from all liability in the case of damage to personnel or property The manufacturing company is...

Page 5: ...ct itself 4 During the warranty period for any defect in workmanship and material all parts and labor will be covered All warranty claims must be submitted to and conform by all statements and policie...

Page 6: ...ttempt to replace the part This must be performed by a qualified service personnel 7 Always switch off and disconnect the appliance from the power supply before beginning any general cleaning or maint...

Page 7: ...uld light up 3 Set the vacuum time or percentage required the sealing time and the gas injection time if the appliance is equipped with this option 4 Position the bag or bags with product in the chamb...

Page 8: ...s 1 Vacuum cycles are set as described in the chapter Vacuum packaging 2 The SOFT VACUUM option allows the packaging of liquid products 3 All the vacuum packages can be stored in a freezer or cooler C...

Page 9: ...0 Fresh salad parsley 50 50 Yogurt Puff pastry 100 Powdered milk 30 70 Baking powder 100 100 Apples 2 1 97 Sliced bacon 35 65 Sandwich loaf Bread 100 French toast Toasted bread 80 20 Pasta 100 Fresh p...

Page 10: ...air to enter the chamber and allow the lid open During the normal vacuum cycle press the button PUMP GASTRO 6 for 3 seconds to start heating the sealing bar for manual sealing 7 1 1 Control and LCD D...

Page 11: ...g method Press or buttons to choose characters then press SET to move to the next segment By pressing the SET button it is possible to pass over the empty positions and then confirm the set parameters...

Page 12: ...g the chamber is not higher than 14 21 PSI or 1 1 5 bars 4 Printer Label Settings PRINTER OPTION By pressing the SET button the following will appear By using the buttons or it is possible to set the...

Page 13: ...cycle at any time push the ON OFF button for 5 seconds Once the cleaning cycle is complete the screen will revert back to showing the number of programs in use The pump maintenance is not strictly lin...

Page 14: ...Install the new one by pressing in place Close lid and test for a seal 4 Replacement of the Clear Chamber Bell Lid Gasket 5 Replacement of Teflon Sealing Bar The sealing bar needs to be replaced by a...

Page 15: ...e the 2 cables are firmly attached 3 Verify that the distance between the Teflon sealing bar and the silicone sealing bar gasket is at least 125 inches 4 5mm 4 Verify that the Teflon sealing bar is dr...

Page 16: ...16 CHAPTER 10 NAME PLATE AND TECHNICAL DETAILS CONFIGURATION AND CONSUMPTION Image 8 5 Name plate example...

Page 17: ...17 CHAPTER 11...

Page 18: ...18 EXPLODED VIEWS AND PART...

Page 19: ...19 LISTS...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...24 CHAPTER 12 WIRING DIAGRAMS PVS27 PVS32 PVS32G PVS42 PVS42BG PVS5225 PVS52G...

Page 25: ...25...

Page 26: ...26...

Reviews: