background image

CHAPTER 1 

Operation and Care Manual

 

The  operation  and  care  manual  is  a  document 

issued by the manufacturing company and is an 

integral  part  of the  machine.  This document  is 

adequately  identified  for  easy  tracing  and/or 

subsequent references. 

All  rights  relating  to  the  reproduction  and 

disclosure  of  the  information  contained  in  this 

handbook and the documentation quoted and/or 
attached  are  reserved.  This  handbook  contains 

the information necessary for the customer and 

assigned  personnel,  to  ensure  the  correct 

installation,  use  and  maintenance  of  the 

appliance allowing it to be used safely. 

Safety precautions and  

Manufacturer’s

 liabilities. 

Every operations related to the intended use of 

this appliance and its overall life cycle has been 

carefully  and  thoroughly  analysed  by  the 
manufacturing  company  during  the  design 

phase, construction phase and the writing of the 

operation and care manual. 

It  is  nevertheless  understood  that  experience, 

proper 

training  and  “common  sense”  of  the 

personnel  operating  this  appliance  are  of  the 

utmost importance. It is the responsibility of the 

operator  to  observe  all  safety  precautions  as 

outlined  in  this  manual  and  to  operate  this 

appliance accordingly.  

The non-observance of the safety precautions or 

specific  warnings  indicated  in  this  manual,  the 

use of this appliance by unauthorized personnel, 
violation  of  all  safety  standards  regarding  the 

design,  construction,  and  intended  use  of  the 

machine,  will  relieve the  manufacturer from  all 

liability  in  the  case  of  damage  to  personnel  or 

property. 

The  manufacturing  company  is  therefore  in  no 

way responsible for the non-observance on the 

part of the user of the safety precautions listed 

in this manual. 

Regulatory references 

The following manual 

CONFORMS TO

ANSI/UL Std. 963 

 CERT. TO CAN/CSA 

Std.C22.2 No. 68 

 CONFORMS TO NSF 169

Disposal of this appliance after its 

useful life.

 

Electric  and  electronic  appliances  contain 

dangerous substances that may have potentially 

harmful effects for people and the environment. 

It is recommended to dispose of it properly, 

DO 

NOT  DISPOSE  OF  ELECTRICAL  OR 

ELECTRONIC  EQUIPMENT  WITH  OTHER 

MUNICIPAL WASTE. 

CHAPTER 2 

How  to  use  the  Operation  and 

Care Manual 

This document is an integral part of the machine. 

Preserve a copy of this operation manual for the 

entire  working  life  of  the  appliance  even  if 

transferred  or  sold.  Additional  copies  can  be 

obtained from the manufacturer.  

To  maintain  the  operation  and  care  manual  in 

good condition: 

1. Use the operation and care manual carefully

so  as  to  not  to  damage  its  contents.  In

particular,  do  not  leave  the  operation  and

care manual around after use and return it to

its 

proper 

place 

immediately 

after

consultation.

2.

Do not remove, rip out or rewrite parts of the

operation and care manual. Any changes to

this  manual  are  to  be  issued  by  the

manufacturer.

3. Keep the operation and care manual in a safe

place,  away  from  environmental  elements

which could damage it.

Summary of Contents for PrepRite PVS27-6-1

Page 1: ...Vacuum Sealing Machine Operation and Care and Maintenance Manual For PVS27 6 1 PVS32 8 1 PVS32G 8 1 PVS42 12 1 PVS42G 12 2 PVS42GP 12 1 PVS52 25 1 PVS52 25 2 PVS52G 25 2 This appliance is for commerci...

Page 2: ...rstood by all operators and users 1 This appliance must be installed on a stable and level surface 2 DO NOT install this appliance in any area where it may be affected by any adverse conditions such a...

Page 3: ...ersons unplug from the power supply before servicing This appliance must service by qualified service personnel Failure to properly maintain and service to this appliance can and will cause injury or...

Page 4: ...standards regarding the design construction and intended use of the machine will relieve the manufacturer from all liability in the case of damage to personnel or property The manufacturing company is...

Page 5: ...ct itself 4 During the warranty period for any defect in workmanship and material all parts and labor will be covered All warranty claims must be submitted to and conform by all statements and policie...

Page 6: ...ttempt to replace the part This must be performed by a qualified service personnel 7 Always switch off and disconnect the appliance from the power supply before beginning any general cleaning or maint...

Page 7: ...uld light up 3 Set the vacuum time or percentage required the sealing time and the gas injection time if the appliance is equipped with this option 4 Position the bag or bags with product in the chamb...

Page 8: ...s 1 Vacuum cycles are set as described in the chapter Vacuum packaging 2 The SOFT VACUUM option allows the packaging of liquid products 3 All the vacuum packages can be stored in a freezer or cooler C...

Page 9: ...0 Fresh salad parsley 50 50 Yogurt Puff pastry 100 Powdered milk 30 70 Baking powder 100 100 Apples 2 1 97 Sliced bacon 35 65 Sandwich loaf Bread 100 French toast Toasted bread 80 20 Pasta 100 Fresh p...

Page 10: ...air to enter the chamber and allow the lid open During the normal vacuum cycle press the button PUMP GASTRO 6 for 3 seconds to start heating the sealing bar for manual sealing 7 1 1 Control and LCD D...

Page 11: ...g method Press or buttons to choose characters then press SET to move to the next segment By pressing the SET button it is possible to pass over the empty positions and then confirm the set parameters...

Page 12: ...g the chamber is not higher than 14 21 PSI or 1 1 5 bars 4 Printer Label Settings PRINTER OPTION By pressing the SET button the following will appear By using the buttons or it is possible to set the...

Page 13: ...cycle at any time push the ON OFF button for 5 seconds Once the cleaning cycle is complete the screen will revert back to showing the number of programs in use The pump maintenance is not strictly lin...

Page 14: ...Install the new one by pressing in place Close lid and test for a seal 4 Replacement of the Clear Chamber Bell Lid Gasket 5 Replacement of Teflon Sealing Bar The sealing bar needs to be replaced by a...

Page 15: ...e the 2 cables are firmly attached 3 Verify that the distance between the Teflon sealing bar and the silicone sealing bar gasket is at least 125 inches 4 5mm 4 Verify that the Teflon sealing bar is dr...

Page 16: ...16 CHAPTER 10 NAME PLATE AND TECHNICAL DETAILS CONFIGURATION AND CONSUMPTION Image 8 5 Name plate example...

Page 17: ...17 CHAPTER 11...

Page 18: ...18 EXPLODED VIEWS AND PART...

Page 19: ...19 LISTS...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...24 CHAPTER 12 WIRING DIAGRAMS PVS27 PVS32 PVS32G PVS42 PVS42BG PVS5225 PVS52G...

Page 25: ...25...

Page 26: ...26...

Reviews: