16
ENGLISH
When the temperature taken by the core probe reaches the end-of-hard-cooling phase the control
panel will automatically switch to the cooling phase.
During the cooling phase, the display will show the temperature taken by the core probe, the cell
temperature, the name of the program (if any) and the time elapsed since the starting of the cooling
process.
►
If the temperature taken by the core probe reaches the end-of-cooling temperature within the co-
oling phase time limit , the cooling will be completely successful, the control panel will automatically
switch to the preservation phase and the buzzer will sound.
►
To silence buzzer press and release any key.
Program: MANUAL
Cycle time: 70 min
End
►
During preservation the display will show the cell tem-
perature, the name of the program (if any) and the time
taken to complete the cooling phase successfully.
►
If the temperature taken by the core probe does not
reach the end-of-cooling temperature within the cooling
phase time limit , the cooling will not be successfully com-
pleted but it will go on working and the buzzer will sound.
►
To restore the normal display and to silence buzzer
press and release any key.
Program: MANUAL
Cycle time: 100 min
End
►
When the temperature taken by the core probe rea-
ches the end-of-cooling temperature , the control panel
will automatically switch to the preservation phase as
stated above.
9.2.7 Time Positive Temperature Cooling
Time cooling and preservation cycle consists of the following two phases:
►
Cooling
►
Preservation
When a phase is over the control panel automatically switches to the next step.
To start the cycle proceed as follows:
- Make sure the display is in the “ON” mode.
- Make sure the keyboard is not locked and no procedure is currently under process.